summaryrefslogtreecommitdiff
path: root/man/iocost.conf.xml
blob: be742442673b2fc61fba3561cfc9e38bf523b0d5 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
<?xml version='1.0'?>
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
  "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->

<refentry id="iocost.conf" xmlns:xi="http://www.w3.org/2001/XInclude">
  <refentryinfo>
    <title>iocost.conf</title>
    <productname>systemd</productname>
  </refentryinfo>

  <refmeta>
    <refentrytitle>iocost.conf</refentrytitle>
    <manvolnum>5</manvolnum>
  </refmeta>

  <refnamediv>
    <refname>iocost.conf</refname>
    <refpurpose>Configuration files for the iocost solution manager</refpurpose>
  </refnamediv>

  <refsynopsisdiv>
    <para>
      <filename>/etc/systemd/iocost.conf</filename>
      <filename>/etc/systemd/iocost.conf.d/*.conf</filename>
    </para>
  </refsynopsisdiv>

  <refsect1>
    <title>Description</title>

    <para>This file configures the behavior of <literal>iocost</literal>, a tool mostly used by
    <citerefentry><refentrytitle>systemd-udevd</refentrytitle><manvolnum>8</manvolnum></citerefentry> rules
    to automatically apply I/O cost solutions to <filename>/sys/fs/cgroup/io.cost.*</filename>.</para>

    <para>The qos and model values are calculated based on benchmarks collected on the
    <ulink url="https://github.com/iocost-benchmark/iocost-benchmarks">iocost-benchmark</ulink>
    project and turned into a set of solutions that go from most to least isolated.
    Isolation allows the system to remain responsive in face of high I/O load.
    Which solutions are available for a device can be queried from the udev metadata attached to it. By
    default the naive solution is used, which provides the most bandwidth.</para>
  </refsect1>

  <xi:include href="standard-conf.xml" xpointer="main-conf" />

  <refsect1>
    <title>Options</title>

    <para>All options are configured in the [IOCost] section:</para>

    <variablelist class='config-directives'>

      <varlistentry>
        <term><varname>TargetSolution=</varname></term>

        <listitem><para>Chooses which I/O cost solution (identified by named string) should be used
        for the devices in this system. The known solutions can be queried from the udev metadata
        attached to the devices. If a device does not have the specified solution, the first one
        listed in <varname>IOCOST_SOLUTIONS</varname> is used instead.</para>

        <para>E.g. <literal>TargetSolution=isolated-bandwidth</literal>.</para></listitem>
      </varlistentry>
    </variablelist>
  </refsect1>

  <refsect1>
    <title>See Also</title>
    <para>
      <citerefentry><refentrytitle>udevadm</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
      <ulink url="https://github.com/iocost-benchmark/iocost-benchmarks">The iocost-benchmarks github project</ulink>,
      <ulink url="https://github.com/facebookexperimental/resctl-demo/tree/main/resctl-bench/doc">The resctl-bench
      documentation details how the values are obtained</ulink>
    </para>
  </refsect1>

</refentry>