diff options
Diffstat (limited to 'mysql-test/t/init_connect_basic.test')
-rw-r--r-- | mysql-test/t/init_connect_basic.test | 151 |
1 files changed, 0 insertions, 151 deletions
diff --git a/mysql-test/t/init_connect_basic.test b/mysql-test/t/init_connect_basic.test deleted file mode 100644 index 8557dfbf4fc..00000000000 --- a/mysql-test/t/init_connect_basic.test +++ /dev/null @@ -1,151 +0,0 @@ -############## mysql-test\t\init_connect_basic.test ########################### -# # -# Variable Name: init_connect # -# Scope: GLOBAL # -# Access Type: Dynamic # -# Data Type: string # -# Default Value: # -# Range: # -# # -# # -# Creation Date: 2008-02-07 # -# Author: Rizwan # -# # -# Description: Test Cases of Dynamic System Variable init_connect # -# that checks the behavior of this variable in the following ways# -# * Default Value # -# * Valid & Invalid values # -# * Scope & Access method # -# * Data Integrity # -# # -# Reference: http://dev.mysql.com/doc/refman/5.1/en/ # -# server-system-variables.html # -# # -############################################################################### - ---source include/load_sysvars.inc -############################################## -## START OF init_connect TESTS ## -############################################## - -############################################################# -# Save initial value # -############################################################# -# save using implicit session scope -SET @global_start_value = @@global.init_connect; -SELECT @global_start_value AS INIT_VALUE; - ---echo '#--------------------FN_DYNVARS_036_01------------------#' -############################################################################### -# Test Variable access and assignment with and without @@ # -############################################################################### -# select without @@ ---error ER_BAD_FIELD_ERROR -SELECT init_connect; -# access using no scope specified -SELECT @@init_connect; -# assign value without @@ -SET @@global.init_connect='SET autocomit=0'; -SELECT @@global.init_connect; -# using another syntax for accessing session variable -SET global init_connect='SET autocomit=0'; -# accessing variable with scope the wrong way ---Error ER_BAD_FIELD_ERROR -SELECT global init_connect; ---Error ER_PARSE_ERROR -SELECT @@global init_connect; - - ---echo '#--------------------FN_DYNVARS_036_02-------------------------#' -################################################################## -# Check the DEFAULT value of init_connect for global # -################################################################## -SET @@global.init_connect = 'SET join_buffer_size=8200'; -SET @@global.init_connect = DEFAULT; -SELECT @@global.init_connect; - ---echo '#--------------------FN_DYNVARS_036_03-------------------------#' -###################################################################### -# see if it is accessable using session scope # -###################################################################### ---Error ER_GLOBAL_VARIABLE -SET @@session.init_connect = ''; ---Error ER_GLOBAL_VARIABLE -SET @@init_connect = ''; ---Error ER_INCORRECT_GLOBAL_LOCAL_VAR -SELECT @@session.init_connect; ---Error ER_INCORRECT_GLOBAL_LOCAL_VAR -SELECT @@local.init_connect; - ---echo '#--------------------FN_DYNVARS_036_04-------------------------#' -######################################################################### -# Change the value of init_connect to a valid value # -######################################################################### - -SET @@global.init_connect=""; -SELECT @@global.init_connect; - -SET @@global.init_connect='SELECT 1,"abc"'; -SELECT @@global.init_connect; - -SET @@global.init_connect='SET @yoursql="mysql"'; -SELECT @@global.init_connect; - -SET @@global.init_connect="SET autocomit=0;REVOKE ALL ON INFORMATION_SCHEMA.*"; -SELECT @@global.init_connect; - -SET @@global.init_connect='SHOW VARIABLES'; -SELECT @@global.init_connect; - -SET @@global.init_connect = NULL; -SELECT @@global.init_connect; - -#any string is accepted as valid value as its is not verified until runtime -SET @@global.init_connect='abc 123 +-*/'; -SELECT @@global.init_connect; - -SET @@global.init_connect=this_will_give_syntax_error; -SELECT @@global.init_connect; - -SET @@global.init_connect = init_slave; -SELECT @@global.init_connect; - ---echo '#--------------------FN_DYNVARS_036_05-------------------------#' -########################################################################### -# Change the value of init_connect to an invalid value for global # -########################################################################### - ---Error ER_WRONG_TYPE_FOR_VAR -SET @@global.init_connect = true; ---Error ER_WRONG_TYPE_FOR_VAR -SET @@global.init_connect = false; ---Error ER_WRONG_TYPE_FOR_VAR -SET @@global.init_connect = 1.1; ---Error ER_WRONG_TYPE_FOR_VAR -SET @@global.init_connect = 0; ---Error ER_WRONG_TYPE_FOR_VAR -SET @@global.init_connect = 1; ---Error ER_WRONG_TYPE_FOR_VAR -SET @@global.init_connect = -1; - -SET @@global.init_connect = ON; -SELECT @@global.init_connect; - ---echo '#--------------------FN_DYNVARS_036_06-------------------------#' -############################################################################## -# Check if the value in GLOBAL Table matches value in variable # -############################################################################## - -SELECT @@global.init_connect = (SELECT VARIABLE_VALUE -FROM INFORMATION_SCHEMA.GLOBAL_VARIABLES -WHERE VARIABLE_NAME='init_connect') AS res; - -#################################### -# Restore initial value # -#################################### -SET @@global.init_connect = @global_start_value; -SELECT @@global.init_connect; - -##################################################### -# END OF init_connect TESTS # -##################################################### |