summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorMike Crowe <mac@mcrowe.com>2019-06-24 20:18:00 +0000
committerAdhemerval Zanella <adhemerval.zanella@linaro.org>2019-07-02 14:12:29 -0300
commita53662bcb25094bfb79507585af8972f3b6d789f (patch)
tree8aa7bbad65b4ab42dfda0581c2d48d482f6eaaf6
parent6df32fd016ae8d6e39fbbc3a7fa40b1b608142a3 (diff)
downloadglibc-azanella/master-posix_clock.tar.gz
nptl: Remove futex_supports_exact_relative_timeoutsazanella/master-posix_clock
The only implementation of futex_supports_exact_relative_timeouts always returns true. Let's remove it and all its callers. * nptl/pthread_cond_wait.c: (__pthread_cond_clockwait): Remove code that is only useful if futex_supports_exact_relative_timeouts () returns false. * nptl/pthread_condattr_setclock.c: (pthread_condattr_setclock): Likewise. * sysdeps/nptl/futex-internal.h: Remove comment about relative timeouts potentially being imprecise since it's no longer true. Remove declaration of futex_supports_exact_relative_timeouts. * sysdeps/unix/sysv/linux/futex-internal.h: Remove implementation of futex_supports_exact_relative_timeouts. Reviewed-by: Adhemerval Zanella <adhemerval.zanella@linaro.org>
-rw-r--r--ChangeLog11
-rw-r--r--nptl/pthread_cond_wait.c5
-rw-r--r--nptl/pthread_condattr_setclock.c5
-rw-r--r--sysdeps/nptl/futex-internal.h9
-rw-r--r--sysdeps/unix/sysv/linux/futex-internal.h8
5 files changed, 12 insertions, 26 deletions
diff --git a/ChangeLog b/ChangeLog
index f2cb99f2c2..ab8bdd2aea 100644
--- a/ChangeLog
+++ b/ChangeLog
@@ -1,5 +1,16 @@
2019-07-02 Mike Crowe <mac@mcrowe.com>
+ * nptl/pthread_cond_wait.c: (__pthread_cond_clockwait): Remove code
+ that is only useful if futex_supports_exact_relative_timeouts ()
+ returns false.
+ * nptl/pthread_condattr_setclock.c: (pthread_condattr_setclock):
+ Likewise.
+ * sysdeps/nptl/futex-internal.h: Remove comment about relative
+ timeouts potentially being imprecise since it's no longer true.
+ Remove declaration of futex_supports_exact_relative_timeouts.
+ * sysdeps/unix/sysv/linux/futex-internal.h: Remove implementation
+ of futex_supports_exact_relative_timeouts.
+
* NEWS: Mention recently-added pthread_cond_clockwait,
pthread_rwlock_clockrdlock, pthread_rwlock_clockwrlock and
sem_clockwait functions.
diff --git a/nptl/pthread_cond_wait.c b/nptl/pthread_cond_wait.c
index 68ec754003..450bf66b34 100644
--- a/nptl/pthread_cond_wait.c
+++ b/nptl/pthread_cond_wait.c
@@ -674,11 +674,6 @@ __pthread_cond_clockwait (pthread_cond_t *cond, pthread_mutex_t *mutex,
if (!futex_abstimed_supported_clockid (clockid))
return EINVAL;
- /* If we do not support waiting using CLOCK_MONOTONIC, return an error. */
- if (clockid == CLOCK_MONOTONIC
- && !futex_supports_exact_relative_timeouts ())
- return EINVAL;
-
return __pthread_cond_wait_common (cond, mutex, clockid, abstime);
}
weak_alias (__pthread_cond_clockwait, pthread_cond_clockwait);
diff --git a/nptl/pthread_condattr_setclock.c b/nptl/pthread_condattr_setclock.c
index 641a041fca..ac91923522 100644
--- a/nptl/pthread_condattr_setclock.c
+++ b/nptl/pthread_condattr_setclock.c
@@ -33,11 +33,6 @@ pthread_condattr_setclock (pthread_condattr_t *attr, clockid_t clock_id)
in the pthread_cond_t structure needs to be adjusted. */
return EINVAL;
- /* If we do not support waiting using CLOCK_MONOTONIC, return an error. */
- if (clock_id == CLOCK_MONOTONIC
- && !futex_supports_exact_relative_timeouts())
- return ENOTSUP;
-
/* Make sure the value fits in the bits we reserved. */
assert (clock_id < (1 << COND_CLOCK_BITS));
diff --git a/sysdeps/nptl/futex-internal.h b/sysdeps/nptl/futex-internal.h
index f29d6d48b2..dff2317b07 100644
--- a/sysdeps/nptl/futex-internal.h
+++ b/sysdeps/nptl/futex-internal.h
@@ -51,8 +51,7 @@
Both absolute and relative timeouts can be used. An absolute timeout
expires when the given specific point in time on the specified clock
passes, or when it already has passed. A relative timeout expires when
- the given duration of time on the CLOCK_MONOTONIC clock passes. Relative
- timeouts may be imprecise (see futex_supports_exact_relative_timeouts).
+ the given duration of time on the CLOCK_MONOTONIC clock passes.
Due to POSIX requirements on when synchronization data structures such
as mutexes or semaphores can be destroyed and due to the futex design
@@ -81,12 +80,6 @@
static __always_inline int
futex_supports_pshared (int pshared);
-/* Returns true if relative timeouts are robust to concurrent changes to the
- system clock. If this returns false, relative timeouts can still be used
- but might be effectively longer or shorter than requested. */
-static __always_inline bool
-futex_supports_exact_relative_timeouts (void);
-
/* Atomically wrt other futex operations on the same futex, this blocks iff
the value *FUTEX_WORD matches the expected value. This is
semantically equivalent to:
diff --git a/sysdeps/unix/sysv/linux/futex-internal.h b/sysdeps/unix/sysv/linux/futex-internal.h
index 299d2489f9..980b7987c3 100644
--- a/sysdeps/unix/sysv/linux/futex-internal.h
+++ b/sysdeps/unix/sysv/linux/futex-internal.h
@@ -46,14 +46,6 @@ futex_supports_pshared (int pshared)
return EINVAL;
}
-/* The Linux kernel supports relative timeouts measured against the
- CLOCK_MONOTONIC clock. */
-static __always_inline bool
-futex_supports_exact_relative_timeouts (void)
-{
- return true;
-}
-
/* See sysdeps/nptl/futex-internal.h for details. */
static __always_inline int