diff options
Diffstat (limited to 'ironic/conf')
-rw-r--r-- | ironic/conf/__init__.py | 4 | ||||
-rw-r--r-- | ironic/conf/conductor.py | 35 | ||||
-rw-r--r-- | ironic/conf/fake.py | 85 | ||||
-rw-r--r-- | ironic/conf/opts.py | 1 | ||||
-rw-r--r-- | ironic/conf/sensor_data.py | 89 |
5 files changed, 179 insertions, 35 deletions
diff --git a/ironic/conf/__init__.py b/ironic/conf/__init__.py index c1a893181..648395362 100644 --- a/ironic/conf/__init__.py +++ b/ironic/conf/__init__.py @@ -29,6 +29,7 @@ from ironic.conf import deploy from ironic.conf import dhcp from ironic.conf import dnsmasq from ironic.conf import drac +from ironic.conf import fake from ironic.conf import glance from ironic.conf import healthcheck from ironic.conf import ibmc @@ -44,6 +45,7 @@ from ironic.conf import neutron from ironic.conf import nova from ironic.conf import pxe from ironic.conf import redfish +from ironic.conf import sensor_data from ironic.conf import service_catalog from ironic.conf import snmp from ironic.conf import swift @@ -65,6 +67,7 @@ deploy.register_opts(CONF) drac.register_opts(CONF) dhcp.register_opts(CONF) dnsmasq.register_opts(CONF) +fake.register_opts(CONF) glance.register_opts(CONF) healthcheck.register_opts(CONF) ibmc.register_opts(CONF) @@ -80,6 +83,7 @@ neutron.register_opts(CONF) nova.register_opts(CONF) pxe.register_opts(CONF) redfish.register_opts(CONF) +sensor_data.register_opts(CONF) service_catalog.register_opts(CONF) snmp.register_opts(CONF) swift.register_opts(CONF) diff --git a/ironic/conf/conductor.py b/ironic/conf/conductor.py index 2161b9434..653e30f56 100644 --- a/ironic/conf/conductor.py +++ b/ironic/conf/conductor.py @@ -97,41 +97,6 @@ opts = [ cfg.IntOpt('node_locked_retry_interval', default=1, help=_('Seconds to sleep between node lock attempts.')), - cfg.BoolOpt('send_sensor_data', - default=False, - help=_('Enable sending sensor data message via the ' - 'notification bus')), - cfg.IntOpt('send_sensor_data_interval', - default=600, - min=1, - help=_('Seconds between conductor sending sensor data message ' - 'to ceilometer via the notification bus.')), - cfg.IntOpt('send_sensor_data_workers', - default=4, min=1, - help=_('The maximum number of workers that can be started ' - 'simultaneously for send data from sensors periodic ' - 'task.')), - cfg.IntOpt('send_sensor_data_wait_timeout', - default=300, - help=_('The time in seconds to wait for send sensors data ' - 'periodic task to be finished before allowing periodic ' - 'call to happen again. Should be less than ' - 'send_sensor_data_interval value.')), - cfg.ListOpt('send_sensor_data_types', - default=['ALL'], - help=_('List of comma separated meter types which need to be' - ' sent to Ceilometer. The default value, "ALL", is a ' - 'special value meaning send all the sensor data.')), - cfg.BoolOpt('send_sensor_data_for_undeployed_nodes', - default=False, - help=_('The default for sensor data collection is to only ' - 'collect data for machines that are deployed, however ' - 'operators may desire to know if there are failures ' - 'in hardware that is not presently in use. ' - 'When set to true, the conductor will collect sensor ' - 'information from all nodes when sensor data ' - 'collection is enabled via the send_sensor_data ' - 'setting.')), cfg.IntOpt('sync_local_state_interval', default=180, help=_('When conductors join or leave the cluster, existing ' diff --git a/ironic/conf/fake.py b/ironic/conf/fake.py new file mode 100644 index 000000000..8f6d75ee3 --- /dev/null +++ b/ironic/conf/fake.py @@ -0,0 +1,85 @@ +# +# Copyright 2022 Red Hat, Inc. +# +# Licensed under the Apache License, Version 2.0 (the "License"); you may +# not use this file except in compliance with the License. You may obtain +# a copy of the License at +# +# http://www.apache.org/licenses/LICENSE-2.0 +# +# Unless required by applicable law or agreed to in writing, software +# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT +# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the +# License for the specific language governing permissions and limitations +# under the License. + +from oslo_config import cfg + +from ironic.common.i18n import _ + +opts = [ + cfg.StrOpt('power_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'power driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('boot_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'boot driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('deploy_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'deploy driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('vendor_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'vendor driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('management_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'management driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('inspect_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'inspect driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('raid_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'raid driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('bios_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'bios driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('storage_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'storage driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), + cfg.StrOpt('rescue_delay', + default='0', + help=_('Delay in seconds for operations with the fake ' + 'rescue driver. Two comma-delimited values will ' + 'result in a delay with a triangular random ' + 'distribution, weighted on the first value.')), +] + + +def register_opts(conf): + conf.register_opts(opts, group='fake') diff --git a/ironic/conf/opts.py b/ironic/conf/opts.py index 846949893..a7ebcfb30 100644 --- a/ironic/conf/opts.py +++ b/ironic/conf/opts.py @@ -43,6 +43,7 @@ _opts = [ ('nova', ironic.conf.nova.list_opts()), ('pxe', ironic.conf.pxe.opts), ('redfish', ironic.conf.redfish.opts), + ('sensor_data', ironic.conf.sensor_data.opts), ('service_catalog', ironic.conf.service_catalog.list_opts()), ('snmp', ironic.conf.snmp.opts), ('swift', ironic.conf.swift.list_opts()), diff --git a/ironic/conf/sensor_data.py b/ironic/conf/sensor_data.py new file mode 100644 index 000000000..8527113a6 --- /dev/null +++ b/ironic/conf/sensor_data.py @@ -0,0 +1,89 @@ +# +# Licensed under the Apache License, Version 2.0 (the "License"); you may +# not use this file except in compliance with the License. You may obtain +# a copy of the License at +# +# http://www.apache.org/licenses/LICENSE-2.0 +# +# Unless required by applicable law or agreed to in writing, software +# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT +# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the +# License for the specific language governing permissions and limitations +# under the License. + +from oslo_config import cfg + +from ironic.common.i18n import _ + +opts = [ + cfg.BoolOpt('send_sensor_data', + default=False, + deprecated_group='conductor', + deprecated_name='send_sensor_data', + help=_('Enable sending sensor data message via the ' + 'notification bus.')), + cfg.IntOpt('interval', + default=600, + min=1, + deprecated_group='conductor', + deprecated_name='send_sensor_data_interval', + help=_('Seconds between conductor sending sensor data message ' + 'via the notification bus. This was originally for ' + 'consumption via ceilometer, but the data may also ' + 'be consumed via a plugin like ' + 'ironic-prometheus-exporter or any other message bus ' + 'data collector.')), + cfg.IntOpt('workers', + default=4, min=1, + deprecated_group='conductor', + deprecated_name='send_sensor_data_workers', + help=_('The maximum number of workers that can be started ' + 'simultaneously for send data from sensors periodic ' + 'task.')), + cfg.IntOpt('wait_timeout', + default=300, + deprecated_group='conductor', + deprecated_name='send_sensor_data_wait_timeout', + help=_('The time in seconds to wait for send sensors data ' + 'periodic task to be finished before allowing periodic ' + 'call to happen again. Should be less than ' + 'send_sensor_data_interval value.')), + cfg.ListOpt('data_types', + default=['ALL'], + deprecated_group='conductor', + deprecated_name='send_sensor_data_types', + help=_('List of comma separated meter types which need to be ' + 'sent to Ceilometer. The default value, "ALL", is a ' + 'special value meaning send all the sensor data. ' + 'This setting only applies to baremetal sensor data ' + 'being processed through the conductor.')), + cfg.BoolOpt('enable_for_undeployed_nodes', + default=False, + deprecated_group='conductor', + deprecated_name='send_sensor_data_for_undeployed_nodes', + help=_('The default for sensor data collection is to only ' + 'collect data for machines that are deployed, however ' + 'operators may desire to know if there are failures ' + 'in hardware that is not presently in use. ' + 'When set to true, the conductor will collect sensor ' + 'information from all nodes when sensor data ' + 'collection is enabled via the send_sensor_data ' + 'setting.')), + cfg.BoolOpt('enable_for_conductor', + default=True, + help=_('If to include sensor metric data for the Conductor ' + 'process itself in the message payload for sensor ' + 'data which allows operators to gather instance ' + 'counts of actions and states to better manage ' + 'the deployment.')), + cfg.BoolOpt('enable_for_nodes', + default=True, + help=_('If to transmit any sensor data for any nodes under ' + 'this conductor\'s management. This option superceeds ' + 'the ``send_sensor_data_for_undeployed_nodes`` ' + 'setting.')), +] + + +def register_opts(conf): + conf.register_opts(opts, group='sensor_data') |