1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
|
=head1 NAME
virsh - management user interface
=head1 SYNOPSIS
B<virsh> [I<OPTION>]... [I<COMMAND_STRING>]
B<virsh> [I<OPTION>]... I<COMMAND> [I<ARG>]...
=head1 DESCRIPTION
The B<virsh> program is the main interface for managing virsh guest
domains. The program can be used to create, pause, and shutdown
domains. It can also be used to list current domains. Libvirt is a C
toolkit to interact with the virtualization capabilities of recent
versions of Linux (and other OSes). It is free software available
under the GNU Lesser General Public License. Virtualization of the
Linux Operating System means the ability to run multiple instances of
Operating Systems concurrently on a single hardware system where the
basic resources are driven by a Linux instance. The library aims at
providing a long term stable C API. It currently supports Xen, QEMU,
KVM, LXC, OpenVZ, VirtualBox and VMware ESX.
The basic structure of most virsh usage is:
virsh [OPTION]... <command> <domain> [ARG]...
Where I<command> is one of the commands listed below; I<domain> is the
numeric domain id, or the domain name, or the domain UUID; and I<ARGS>
are command specific options. There are a few exceptions to this rule
in the cases where the command in question acts on all domains, the
entire machine, or directly on the xen hypervisor. Those exceptions
will be clear for each of those commands. Note: it is permissible to
give numeric names to domains, however, doing so will result in a
domain that can only be identified by domain id. In other words, if a
numeric value is supplied it will be interpreted as a domain id, not
as a name.
The B<virsh> program can be used either to run one I<COMMAND> by giving the
command and its arguments on the shell command line, or a I<COMMAND_STRING>
which is a single shell argument consisting of multiple I<COMMAND> actions
and their arguments joined with whitespace, and separated by semicolons
between commands. Within I<COMMAND_STRING>, virsh understands the
same single, double, and backslash escapes as the shell, although you must
add another layer of shell escaping in creating the single shell argument.
If no command is given in the command line, B<virsh> will then start a minimal
interpreter waiting for your commands, and the B<quit> command will then exit
the program.
The B<virsh> program understands the following I<OPTIONS>.
=over 4
=item B<-c>, B<--connect> I<URI>
Connect to the specified I<URI>, as if by the B<connect> command,
instead of the default connection.
=item B<-d>, B<--debug> I<LEVEL>
Enable debug messages at integer I<LEVEL> and above. I<LEVEL> can
range from 0 to 4 (default). See the documentation of B<VIRSH_DEBUG>
environment variable below for the description of each I<LEVEL>.
=item B<-e>, B<--escape> I<string>
Set alternative escape sequence for I<console> command. By default,
telnet's B<^]> is used. Allowed characters when using hat notation are:
alphabetic character, @, [, ], \, ^, _.
=item B<-h>, B<--help>
Ignore all other arguments, and behave as if the B<help> command were
given instead.
=item B<-k>, B<--keepalive-interval> I<INTERVAL>
Set an I<INTERVAL> (in seconds) for sending keepalive messages to
check whether connection to the server is still alive. Setting the
interval to 0 disables client keepalive mechanism.
=item B<-K>, B<--keepalive-count> I<COUNT>
Set a number of times keepalive message can be sent without getting an
answer from the server without marking the connection dead. There is
no effect to this setting in case the I<INTERVAL> is set to 0.
=item B<-l>, B<--log> I<FILE>
Output logging details to I<FILE>.
=item B<-q>, B<--quiet>
Avoid extra informational messages.
=item B<-r>, B<--readonly>
Make the initial connection read-only, as if by the I<--readonly>
option of the B<connect> command.
=item B<-t>, B<--timing>
Output elapsed time information for each command.
=item B<-v>, B<--version[=short]>
Ignore all other arguments, and prints the version of the libvirt library
virsh is coming from
=item B<-V>, B<--version=long>
Ignore all other arguments, and prints the version of the libvirt library
virsh is coming from and which options and driver are compiled in.
=back
=head1 NOTES
Most B<virsh> operations rely upon the libvirt library being able to
connect to an already running libvirtd service. This can usually be
done using the command B<service libvirtd start>.
Most B<virsh> commands require root privileges to run due to the
communications channels used to talk to the hypervisor. Running as
non root will return an error.
Most B<virsh> commands act synchronously, except maybe shutdown,
setvcpus and setmem. In those cases the fact that the B<virsh>
program returned, may not mean the action is complete and you
must poll periodically to detect that the guest completed the
operation.
B<virsh> strives for backward compatibility. Although the B<help>
command only lists the preferred usage of a command, if an older
version of B<virsh> supported an alternate spelling of a command or
option (such as I<--tunnelled> instead of I<--tunneled>), then
scripts using that older spelling will continue to work.
Several B<virsh> commands take an optionally scaled integer; if no
scale is provided, then the default is listed in the command (for
historical reasons, some commands default to bytes, while other
commands default to kibibytes). The following case-insensitive
suffixes can be used to select a specific scale:
b, byte byte 1
KB kilobyte 1,000
k, KiB kibibyte 1,024
MB megabyte 1,000,000
M, MiB mebibyte 1,048,576
GB gigabyte 1,000,000,000
G, GiB gibibyte 1,073,741,824
TB terabyte 1,000,000,000,000
T, TiB tebibyte 1,099,511,627,776
PB petabyte 1,000,000,000,000,000
P, PiB pebibyte 1,125,899,906,842,624
EB exabyte 1,000,000,000,000,000,000
E, EiB exbibyte 1,152,921,504,606,846,976
=head1 GENERIC COMMANDS
The following commands are generic i.e. not specific to a domain.
=over 4
=item B<help> [I<command-or-group>]
This lists each of the virsh commands. When used without options, all
commands are listed, one per line, grouped into related categories,
displaying the keyword for each group.
To display only commands for a specific group, give the keyword for that
group as an option. For example:
virsh # help host
Host and Hypervisor (help keyword 'host'):
capabilities capabilities
cpu-models show the CPU models for an architecture
connect (re)connect to hypervisor
freecell NUMA free memory
hostname print the hypervisor hostname
qemu-attach Attach to existing QEMU process
qemu-monitor-command QEMU Monitor Command
qemu-agent-command QEMU Guest Agent Command
sysinfo print the hypervisor sysinfo
uri print the hypervisor canonical URI
To display detailed information for a specific command, give its name as the
option instead. For example:
virsh # help list
NAME
list - list domains
SYNOPSIS
list [--inactive] [--all]
DESCRIPTION
Returns list of domains.
OPTIONS
--inactive list inactive domains
--all list inactive & active domains
=item B<quit>, B<exit>
quit this interactive terminal
=item B<version> [I<--daemon>]
Will print out the major version info about what this built from.
If I<--daemon> is specified then the version of the libvirt daemon
is included in the output.
=over 4
B<Example>
$ virsh version
Compiled against library: libvirt 1.2.3
Using library: libvirt 1.2.3
Using API: QEMU 1.2.3
Running hypervisor: QEMU 2.0.50
$ virsh version --daemon
Compiled against library: libvirt 1.2.3
Using library: libvirt 1.2.3
Using API: QEMU 1.2.3
Running hypervisor: QEMU 2.0.50
Running against daemon: 1.2.6
=back
=item B<cd> [I<directory>]
Will change current directory to I<directory>. The default directory
for the B<cd> command is the home directory or, if there is no I<HOME>
variable in the environment, the root directory.
This command is only available in interactive mode.
=item B<pwd>
Will print the current directory.
=item B<connect> [I<URI>] [I<--readonly>]
(Re)-Connect to the hypervisor. When the shell is first started, this
is automatically run with the I<URI> parameter requested by the C<-c>
option on the command line. The I<URI> parameter specifies how to
connect to the hypervisor. The documentation page at
L<http://libvirt.org/uri.html> list the values supported, but the most
common are:
=over 4
=item xen:///
this is used to connect to the local Xen hypervisor
=item qemu:///system
connect locally as root to the daemon supervising QEMU and KVM domains
=item qemu:///session
connect locally as a normal user to his own set of QEMU and KVM domains
=item lxc:///
connect to a local linux container
=back
To find the currently used URI, check the I<uri> command documented below.
For remote access see the documentation page at
L<http://libvirt.org/uri.html> on how to make URIs.
The I<--readonly> option allows for read-only connection
=item B<uri>
Prints the hypervisor canonical URI, can be useful in shell mode.
=item B<hostname>
Print the hypervisor hostname.
=item B<sysinfo>
Print the XML representation of the hypervisor sysinfo, if available.
=item B<nodeinfo>
Returns basic information about the node, like number and type of CPU,
and size of the physical memory. The output corresponds to virNodeInfo
structure. Specifically, the "CPU socket(s)" field means number of CPU
sockets per NUMA cell.
=item B<nodecpumap> [I<--pretty>]
Displays the node's total number of CPUs, the number of online CPUs
and the list of online CPUs.
With I<--pretty> the online CPUs are printed as a range instead of a list.
=item B<nodecpustats> [I<cpu>] [I<--percent>]
Returns cpu stats of the node.
If I<cpu> is specified, this will prints specified cpu statistics only.
If I<--percent> is specified, this will prints percentage of each kind of cpu
statistics during 1 second.
=item B<nodememstats> [I<cell>]
Returns memory stats of the node.
If I<cell> is specified, this will prints specified cell statistics only.
=item B<nodesuspend> [I<target>] [I<duration>]
Puts the node (host machine) into a system-wide sleep state and schedule
the node's Real-Time-Clock interrupt to resume the node after the time
duration specified by I<duration> is out.
I<target> specifies the state to which the host will be suspended to, it
can be "mem" (suspend to RAM), "disk" (suspend to disk), or "hybrid"
(suspend to both RAM and disk). I<duration> specifies the time duration
in seconds for which the host has to be suspended, it should be at least
60 seconds.
=item B<node-memory-tune> [I<shm-pages-to-scan>] [I<shm-sleep-millisecs>]
[I<shm-merge-across-nodes>]
Allows you to display or set the node memory parameters.
I<shm-pages-to-scan> can be used to set the number of pages to scan
before the shared memory service goes to sleep; I<shm-sleep-millisecs>
can be used to set the number of millisecs the shared memory service should
sleep before next scan; I<shm-merge-across-nodes> specifies if pages from
different numa nodes can be merged. When set to 0, only pages which physically
reside in the memory area of same NUMA node can be merged. When set to 1,
pages from all nodes can be merged. Default to 1.
B<Note>: Currently the "shared memory service" only means KSM (Kernel Samepage
Merging).
=item B<capabilities>
Print an XML document describing the capabilities of the hypervisor
we are currently connected to. This includes a section on the host
capabilities in terms of CPU and features, and a set of description
for each kind of guest which can be virtualized. For a more complete
description see:
L<http://libvirt.org/formatcaps.html>
The XML also show the NUMA topology information if available.
=item B<domcapabilities> [I<virttype>] [I<emulatorbin>]
[I<arch>] [I<machine>]
Print an XML document describing the domain capabilities for the
hypervisor we are connected to using information either sourced from an
existing domain or taken from the B<virsh capabilities> output. This may
be useful if you intend to create a new domain and are curious if for
instance it could make use of VFIO by creating a domain for the
hypervisor with a specific emulator and architecture.
Each hypervisor will have different requirements regarding which options
are required and which are optional. A hypervisor can support providing
a default value for any of the options.
The I<virttype> option specifies the virtualization type used. The value
to be used is either from the 'type' attribute of the <domain/> top
level element from the domain XML or the 'type' attribute found within
each <guest/> element from the B<virsh capabilities> output. The
I<emulatorbin> option specifies the path to the emulator. The value to
be used is either the <emulator> element in the domain XML or the
B<virsh capabilities> output. The I<arch> option specifies the
architecture to be used for the domain. The value to be used is either
the "arch" attribute from the domain's XML <os/> element and <type/>
subelement or the "name" attribute of an <arch/> element from the
B<virsh capabililites> output. The I<machine> specifies the machine type
for the emulator. The value to be used is either the "machine" attribute
from the domain's XML <os/> element and <type/> subelement or one from a
list of machines from the B<virsh capabilities> output for a specific
architecture and domain type.
For the qemu hypervisor, a I<virttype> of either 'qemu' or 'kvm' must be
supplied along with either the I<emulatorbin> or I<arch> in order to
generate output for the default I<machine>. Supplying a I<machine>
value will generate output for the specific machine.
=item B<inject-nmi> I<domain>
Inject NMI to the guest.
=item B<list> [I<--inactive> | I<--all>]
[I<--managed-save>] [I<--title>]
{ [I<--table>] | I<--name> | I<--uuid> }
[I<--persistent>] [I<--transient>]
[I<--with-managed-save>] [I<--without-managed-save>]
[I<--autostart>] [I<--no-autostart>]
[I<--with-snapshot>] [I<--without-snapshot>]
[I<--state-running>] [I<--state-paused>]
[I<--state-shutoff>] [I<--state-other>]
Prints information about existing domains. If no options are
specified it prints out information about running domains.
An example format for the list is as follows:
B<virsh> list
Id Name State
----------------------------------------------------
0 Domain-0 running
2 fedora paused
Name is the name of the domain. ID the domain numeric id.
State is the run state (see below).
B<STATES>
The State field lists 8 states for a domain, and which ones the
current domain is in.
=over 4
=item B<cpu-models> I<arch>
Print the list of CPU models known for the specified architecture.
=item B<running>
The domain is currently running on a CPU
=item B<idle>
The domain is idle, and not running or runnable. This can be caused
because the domain is waiting on IO (a traditional wait state) or has
gone to sleep because there was nothing else for it to do.
=item B<paused>
The domain has been paused, usually occurring through the administrator
running B<virsh suspend>. When in a paused state the domain will still
consume allocated resources like memory, but will not be eligible for
scheduling by the hypervisor.
=item B<shutdown>
The domain is in the process of shutting down, i.e. the guest operating system
has been notified and should be in the process of stopping its operations
gracefully.
=item B<shut off>
The domain is not running. Usually this indicates the domain has been
shut down completely, or has not been started.
=item B<crashed>
The domain has crashed, which is always a violent ending. Usually
this state can only occur if the domain has been configured not to
restart on crash.
=item B<dying>
The domain is in process of dying, but hasn't completely shutdown or
crashed.
=item B<pmsuspended>
The domain has been suspended by guest power management, e.g. entered
into s3 state.
=back
Normally only active domains are listed. To list inactive domains specify
I<--inactive> or I<--all> to list both active and inactive domains.
To further filter the list of domains you may specify one or more of filtering
flags supported by the B<list> command. These flags are grouped by function.
Specifying one or more flags from a group enables the filter group. Note that
some combinations of flags may yield no results. Supported filtering flags and
groups:
=over 4
=item B<Persistence>
Flag I<--persistent> is used to include persistent domains in the returned
list. To include transient domains specify I<--transient>.
=item B<Existence of managed save image>
To list domains having a managed save image specify flag
I<--with-managed-save>. For domains that don't have a managed save image
specify I<--without-managed-save>.
=item B<Domain state>
The following filter flags select a domain by its state:
I<--state-running> for running domains, I<--state-paused> for paused domains,
I<--state-shutoff> for turned off domains and I<--state-other> for all
other states as a fallback.
=item B<Autostarting domains>
To list autostarting domains use the flag I<--autostart>. To list domains with
this feature disabled use I<--no-autostart>.
=item B<Snapshot existence>
Domains that have snapshot images can be listed using flag I<--with-snapshot>,
domains without a snapshot I<--without-snapshot>.
=back
When talking to older servers, this command is forced to use a series of API
calls with an inherent race, where a domain might not be listed or might appear
more than once if it changed state between calls while the list was being
collected. Newer servers do not have this problem.
If I<--managed-save> is specified, then domains that have managed save state
(only possible if they are in the B<shut off> state, so you need to specify
I<--inactive> or I<--all> to actually list them) will instead show as B<saved>
in the listing. This flag is usable only with the default I<--table> output.
Note that this flag does not filter the list of domains.
If I<--name> is specified, domain names are printed instead of the table
formatted one per line. If I<--uuid> is specified domain's UUID's are printed
instead of names. Flag I<--table> specifies that the legacy table-formatted
output should be used. This is the default. All of these are mutually
exclusive.
If I<--title> is specified, then the short domain description (title) is
printed in an extra column. This flag is usable only with the default
I<--table> output.
Example:
B<virsh> list --title
Id Name State Title
--------------------------------------------------------------------------
0 Domain-0 running Mailserver 1
2 fedora paused
=item B<freecell> [{ [I<--cellno>] B<cellno> | I<--all> }]
Prints the available amount of memory on the machine or within a NUMA
cell. The freecell command can provide one of three different
displays of available memory on the machine depending on the options
specified. With no options, it displays the total free memory on the
machine. With the --all option, it displays the free memory in each
cell and the total free memory on the machine. Finally, with a
numeric argument or with --cellno plus a cell number it will display
the free memory for the specified cell only.
=item B<freepages> [{ [I<--cellno>] I<cellno> [I<--pagesize>] I<pagesize> |
I<--all> }]
Prints the available amount of pages within a NUMA cell. I<cellno> refers
to the NUMA cell you're interested in. I<pagesize> is a scaled integer (see
B<NOTES> above). Alternatively, if I<--all> is used, info on each possible
combination of NUMA cell and page size is printed out.
=item B<allocpages> [I<--pagesize>] I<pagesize> [I<--pagecount>] I<pagecount>
[[I<--cellno>] I<cellno>] [I<--add>] [I<--all>]
Change the size of pages pool of I<pagesize> on the host. If
I<--add> is specified, then I<pagecount> pages are added into the
pool. However, if I<--add> wasn't specified, then the
I<pagecount> is taken as the new absolute size of the pool (this
may be used to free some pages and size the pool down). The
I<cellno> modifier can be used to narrow the modification down to
a single host NUMA cell. On the other end of spectrum lies
I<--all> which executes the modification on all NUMA cells.
=item B<cpu-baseline> I<FILE> [I<--features>]
Compute baseline CPU which will be supported by all host CPUs given in <file>.
The list of host CPUs is built by extracting all <cpu> elements from the
<file>. Thus, the <file> can contain either a set of <cpu> elements separated
by new lines or even a set of complete <capabilities> elements printed by
B<capabilities> command. If I<--features> is specified then the
resulting XML description will explicitly include all features that make
up the CPU, without this option features that are part of the CPU model
will not be listed in the XML description.
=item B<cpu-compare> I<FILE> [I<--error>]
Compare CPU definition from XML <file> with host CPU. The XML <file> may
contain either host or guest CPU definition. The host CPU definition is the
<cpu> element and its contents as printed by B<capabilities> command. The
guest CPU definition is the <cpu> element and its contents from domain XML
definition. For more information on guest CPU definition see:
L<http://libvirt.org/formatdomain.html#elementsCPU>. If I<--error> is
specified, the command will return an error when the given CPU is
incompatible with host CPU and a message providing more details about the
incompatibility will be printed out.
=item B<echo> [I<--shell>] [I<--xml>] [I<arg>...]
Echo back each I<arg>, separated by space. If I<--shell> is
specified, then the output will be single-quoted where needed, so that
it is suitable for reuse in a shell context. If I<--xml> is
specified, then the output will be escaped for use in XML.
=back
=head1 DOMAIN COMMANDS
The following commands manipulate domains directly, as stated
previously most commands take domain as the first parameter. The
I<domain> can be specified as a short integer, a name or a full UUID.
=over 4
=item B<autostart> [I<--disable>] I<domain>
Configure a domain to be automatically started at boot.
The option I<--disable> disables autostarting.
=item B<console> I<domain> [I<devname>] [I<--safe>] [I<--force>]
Connect the virtual serial console for the guest. The optional
I<devname> parameter refers to the device alias of an alternate
console, serial or parallel device configured for the guest.
If omitted, the primary console will be opened.
If the flag I<--safe> is specified, the connection is only attempted
if the driver supports safe console handling. This flag specifies that
the server has to ensure exclusive access to console devices. Optionally
the I<--force> flag may be specified, requesting to disconnect any existing
sessions, such as in a case of a broken connection.
=item B<create> I<FILE> [I<--console>] [I<--paused>] [I<--autodestroy>]
[I<--pass-fds N,M,...>]
Create a domain from an XML <file>. An easy way to create the XML
<file> is to use the B<dumpxml> command to obtain the definition of a
pre-existing guest. The domain will be paused if the I<--paused> option
is used and supported by the driver; otherwise it will be running.
If I<--console> is requested, attach to the console after creation.
If I<--autodestroy> is requested, then the guest will be automatically
destroyed when virsh closes its connection to libvirt, or otherwise
exits.
If I<--pass-fds> is specified, the argument is a comma separated list
of open file descriptors which should be pass on into the guest. The
file descriptors will be re-numbered in the guest, starting from 3. This
is only supported with container based virtualization.
B<Example>
virsh dumpxml <domain> > domain.xml
vi domain.xml (or make changes with your other text editor)
virsh create domain.xml
=item B<define> I<FILE>
Define a domain from an XML <file>. The domain definition is registered
but not started. If domain is already running, the changes will take
effect on the next boot.
=item B<desc> I<domain> [[I<--live>] [I<--config>] |
[I<--current>]] [I<--title>] [I<--edit>] [I<--new-desc>
New description or title message]
Show or modify description and title of a domain. These values are user
fields that allow to store arbitrary textual data to allow easy
identification of domains. Title should be short, although it's not enforced.
(See also B<metadata> that works with XML based domain metadata.)
Flags I<--live> or I<--config> select whether this command works on live
or persistent definitions of the domain. If both I<--live> and I<--config>
are specified, the I<--config> option takes precedence on getting the current
description and both live configuration and config are updated while setting
the description. I<--current> is exclusive and implied if none of these was
specified.
Flag I<--edit> specifies that an editor with the contents of current
description or title should be opened and the contents saved back afterwards.
Flag I<--title> selects operation on the title field instead of description.
If neither of I<--edit> and I<--new-desc> are specified the note or description
is displayed instead of being modified.
=item B<destroy> I<domain> [I<--graceful>]
Immediately terminate the domain I<domain>. This doesn't give the domain
OS any chance to react, and it's the equivalent of ripping the power
cord out on a physical machine. In most cases you will want to use
the B<shutdown> command instead. However, this does not delete any
storage volumes used by the guest, and if the domain is persistent, it
can be restarted later.
If I<domain> is transient, then the metadata of any snapshots will
be lost once the guest stops running, but the snapshot contents still
exist, and a new domain with the same name and UUID can restore the
snapshot metadata with B<snapshot-create>.
If I<--graceful> is specified, don't resort to extreme measures
(e.g. SIGKILL) when the guest doesn't stop after a reasonable timeout;
return an error instead.
=item B<domblkstat> I<domain> [I<block-device>] [I<--human>]
Get device block stats for a running domain. A I<block-device> corresponds
to a unique target name (<target dev='name'/>) or source file (<source
file='name'/>) for one of the disk devices attached to I<domain> (see
also B<domblklist> for listing these names). On a lxc domain, omitting the
I<block-device> yields device block stats summarily for the entire domain.
Use I<--human> for a more human readable output.
Availability of these fields depends on hypervisor. Unsupported fields are
missing from the output. Other fields may appear if communicating with a newer
version of libvirtd.
B<Explanation of fields> (fields appear in the following order):
rd_req - count of read operations
rd_bytes - count of read bytes
wr_req - count of write operations
wr_bytes - count of written bytes
errs - error count
flush_operations - count of flush operations
rd_total_times - total time read operations took (ns)
wr_total_times - total time write operations took (ns)
flush_total_times - total time flush operations took (ns)
<-- other fields provided by hypervisor -->
=item B<domifstat> I<domain> I<interface-device>
Get network interface stats for a running domain.
=item B<domif-setlink> I<domain> I<interface-device> I<state> [I<--config>]
Modify link state of the domain's virtual interface. Possible values for
state are "up" and "down. If I<--config> is specified, only the persistent
configuration of the domain is modified, for compatibility purposes,
I<--persistent> is alias of I<--config>.
I<interface-device> can be the interface's target name or the MAC address.
=item B<domif-getlink> I<domain> I<interface-device> [I<--config>]
Query link state of the domain's virtual interface. If I<--config>
is specified, query the persistent configuration, for compatibility
purposes, I<--persistent> is alias of I<--config>.
I<interface-device> can be the interface's target name or the MAC address.
=item B<domiftune> I<domain> I<interface-device>
[[I<--config>] [I<--live>] | [I<--current>]]
[I<--inbound average,peak,burst>]
[I<--outbound average,peak,burst>]
Set or query the domain's network interface's bandwidth parameters.
I<interface-device> can be the interface's target name (<target dev='name'/>),
or the MAC address.
If no I<--inbound> or I<--outbound> is specified, this command will
query and show the bandwidth settings. Otherwise, it will set the
inbound or outbound bandwidth. I<average,peak,burst> is the same as
in command I<attach-interface>. Values for I<average> and I<peak> are
expressed in kilobytes per second, while I<burst> is expressed in kilobytes
in a single burst at -I<peak> speed as described in the Network XML
documentation at L<http://libvirt.org/formatnetwork.html#elementQoS>.
To clear inbound or outbound settings, use I<--inbound> or I<--outbound>
respectfully with average value of zero.
If I<--live> is specified, affect a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--current> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on hypervisor.
=item B<dommemstat> I<domain> [I<--period> B<seconds>]
[[I<--config>] [I<--live>] | [I<--current>]]
Get memory stats for a running domain.
Depending on the hypervisor a variety of statistics can be returned
For QEMU/KVM with a memory balloon, setting the optional I<--period> to a
value larger than 0 in seconds will allow the balloon driver to return
additional statistics which will be displayed by subsequent B<dommemstat>
commands. Setting the I<--period> to 0 will stop the balloon driver collection,
but does not clear the statistics in the balloon driver. Requires at least
QEMU/KVM 1.5 to be running on the host.
The I<--live>, I<--config>, and I<--current> flags are only valid when using
the I<--period> option in order to set the collection period for the balloon
driver. If I<--live> is specified, only the running guest collection period
is affected. If I<--config> is specified, affect the next boot of a persistent
guest. If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on the guest state.
=item B<domblkerror> I<domain>
Show errors on block devices. This command usually comes handy when
B<domstate> command says that a domain was paused due to I/O error.
The B<domblkerror> command lists all block devices in error state and
the error seen on each of them.
=item B<domblkinfo> I<domain> I<block-device>
Get block device size info for a domain. A I<block-device> corresponds
to a unique target name (<target dev='name'/>) or source file (<source
file='name'/>) for one of the disk devices attached to I<domain> (see
also B<domblklist> for listing these names).
=item B<domblklist> I<domain> [I<--inactive>] [I<--details>]
Print a table showing the brief information of all block devices
associated with I<domain>. If I<--inactive> is specified, query the
block devices that will be used on the next boot, rather than those
currently in use by a running domain. If I<--details> is specified,
disk type and device value will also be printed. Other contexts
that require a block device name (such as I<domblkinfo> or
I<snapshot-create> for disk snapshots) will accept either target
or unique source names printed by this command.
=item B<domstats> [I<--raw>] [I<--enforce>] [I<--state>]
[I<--cpu-total>] [I<--balloon>] [I<--vcpu>] [I<--interface>] [I<--block>]
[[I<--list-active>] [I<--list-inactive>] [I<--list-persistent>]
[I<--list-transient>] [I<--list-running>] [I<--list-paused>]
[I<--list-shutoff>] [I<--list-other>]] | [I<domain> ...]
Get statistics for multiple or all domains. Without any argument this
command prints all available statistics for all domains.
The list of domains to gather stats for can be either limited by listing
the domains as a space separated list, or by specifying one of the
filtering flags I<--list-*>. (The approaches can't be combined.)
By default some of the returned fields may be converted to more
human friendly values by a set of pretty-printers. To suppress this
behavior use the I<--raw> flag.
The individual statistics groups are selectable via specific flags. By
default all supported statistics groups are returned. Supported
statistics groups flags are: I<--state>, I<--cpu-total>, I<--balloon>,
I<--vcpu>, I<--interface>, I<--block>.
When selecting the I<--state> group the following fields are returned:
"state.state" - state of the VM, returned as number from virDomainState enum,
"state.reason" - reason for entering given state, returned as int from,
virDomain*Reason enum corresponding to given state.
I<--cpu-total> returns:
"cpu.time" - total cpu time spent for this domain in nanoseconds,
"cpu.user" - user cpu time spent in nanoseconds,
"cpu.system" - system cpu time spent in nanoseconds
I<--balloon> returns:
"balloon.current" - the memory in kiB currently used,
"balloon.maximum" - the maximum memory in kiB allowed
I<--vcpu> returns:
"vcpu.current" - current number of online virtual CPUs,
"vcpu.maximum" - maximum number of online virtual CPUs,
"vcpu.<num>.state" - state of the virtual CPU <num>, as number
from virVcpuState enum,
"vcpu.<num>.time" - virtual cpu time spent by virtual CPU <num>
I<--interface> returns:
"net.count" - number of network interfaces on this domain,
"net.<num>.name" - name of the interface <num>,
"net.<num>.rx.bytes" - number of bytes received,
"net.<num>.rx.pkts" - number of packets received,
"net.<num>.rx.errs" - number of receive errors,
"net.<num>.rx.drop" - number of receive packets dropped,
"net.<num>.tx.bytes" - number of bytes transmitted,
"net.<num>.tx.pkts" - number of packets transmitted,
"net.<num>.tx.errs" - number of transmission errors,
"net.<num>.tx.drop" - number of transmit packets dropped,
I<block> returns:
"block.count" - number of block devices on this domain,
"block.<num>.name" - name of the target of the block device <num>,
"block.<num>.rd.reqs" - number of read requests,
"block.<num>.rd.bytes" - number of read bytes,
"block.<num>.rd.times" - total time (ns) spent on reads,
"block.<num>.wr.reqs" - number of write requests,
"block.<num>.wr.bytes" - number of written bytes,
"block.<num>.wr.times" - total time (ns) spent on writes,
"block.<num>.fl.reqs" - total flush requests,
"block.<num>.fl.times" - total time (ns) spent on cache flushing,
"block.<num>.errors" - Xen only: the 'oo_req' value,
Selecting a specific statistics groups doesn't guarantee that the
daemon supports the selected group of stats. Flag I<--enforce>
forces the command to fail if the daemon doesn't support the
selected group.
=item B<domiflist> I<domain> [I<--inactive>]
Print a table showing the brief information of all virtual interfaces
associated with I<domain>. If I<--inactive> is specified, query the
virtual interfaces that will be used on the next boot, rather than those
currently in use by a running domain. Other contexts that require a MAC
address of virtual interface (such as I<detach-interface> or
I<domif-setlink>) will accept the MAC address printed by this command.
=item B<blockcommit> I<domain> I<path> [I<bandwidth>]
[I<base>] [I<--shallow>] [I<top>] [I<--delete>] [I<--keep-relative>]
[I<--wait> [I<--async>] [I<--verbose>]] [I<--timeout> B<seconds>]
[I<--active>] [{I<--pivot> | I<--keep-overlay>}]
Reduce the length of a backing image chain, by committing changes at the
top of the chain (snapshot or delta files) into backing images. By
default, this command attempts to flatten the entire chain. If I<base>
and/or I<top> are specified as files within the backing chain, then the
operation is constrained to committing just that portion of the chain;
I<--shallow> can be used instead of I<base> to specify the immediate
backing file of the resulting top image to be committed. The files
being committed are rendered invalid, possibly as soon as the operation
starts; using the I<--delete> flag will attempt to remove these invalidated
files at the successful completion of the commit operation. When the
I<--keep-relative> flag is used, the backing file paths will be kept relative.
When I<top> is omitted or specified as the active image, it is also
possible to specify I<--active> to trigger a two-phase active commit. In
the first phase, I<top> is copied into I<base> and the job can only be
canceled, with top still containing data not yet in base. In the second
phase, I<top> and I<base> remain identical until a call to B<blockjob>
with the I<--abort> flag (keeping top as the active image that tracks
changes from that point in time) or the I<--pivot> flag (making base
the new active image and invalidating top).
By default, this command returns as soon as possible, and data for
the entire disk is committed in the background; the progress of the
operation can be checked with B<blockjob>. However, if I<--wait> is
specified, then this command will block until the operation completes
(or for I<--active>, enters the second phase), or until the operation
is canceled because the optional I<timeout> in seconds elapses
or SIGINT is sent (usually with C<Ctrl-C>). Using I<--verbose> along
with I<--wait> will produce periodic status updates. If job cancellation
is triggered, I<--async> will return control to the user as fast as
possible, otherwise the command may continue to block a little while
longer until the job is done cleaning up. Using I<--pivot> is shorthand
for combining I<--active> I<--wait> with an automatic B<blockjob>
I<--pivot>; and using I<--keep-overlay> is shorthand for combining
I<--active> I<--wait> with an automatic B<blockjob> I<--abort>.
I<path> specifies fully-qualified path of the disk; it corresponds
to a unique target name (<target dev='name'/>) or source file (<source
file='name'/>) for one of the disk devices attached to I<domain> (see
also B<domblklist> for listing these names).
I<bandwidth> specifies copying bandwidth limit in MiB/s, although for
qemu, it may be non-zero only for an online domain. Specifying a negative
value is interpreted as an unsigned long long value or essentially
unlimited. The hypervisor can choose whether to reject the value or
convert it to the maximum value allowed.
=item B<blockcopy> I<domain> I<path> { I<dest> [I<format>] [I<--blockdev>]
| I<xml> } [I<--shallow>] [I<--reuse-external>] [I<bandwidth>]
[I<--wait> [I<--async>] [I<--verbose>]] [{I<--pivot> | I<--finish>}]
[I<--timeout> B<seconds>] [I<granularity>] [I<buf-size>]
Copy a disk backing image chain to a destination. Either I<dest> as
the destination file name, or I<xml> as the name of an XML file containing
a top-level <disk> element describing the destination, must be present.
Additionally, if I<dest> is given, I<format> should be specified to declare
the format of the destination (if I<format> is omitted, then libvirt
will reuse the format of the source, or with I<--reuse-external> will
be forced to probe the destination format, which could be a potential
security hole). The command supports I<--raw> as a boolean flag synonym for
I<--format=raw>. When using I<dest>, the destination is treated as a regular
file unless I<--blockdev> is used to signal that it is a block device. By
default, this command flattens the entire chain; but if I<--shallow> is
specified, the copy shares the backing chain.
If I<--reuse-external> is specified, then the destination must exist and have
sufficient space to hold the copy. If I<--shallow> is used in
conjunction with I<--reuse-external> then the pre-created image must have
guest visible contents identical to guest visible contents of the backing
file of the original image. This may be used to modify the backing file
names on the destination.
By default, the copy job runs in the background, and consists of two
phases. Initially, the job must copy all data from the source, and
during this phase, the job can only be canceled to revert back to the
source disk, with no guarantees about the destination. After this phase
completes, both the source and the destination remain mirrored until a
call to B<blockjob> with the I<--abort> and I<--pivot> flags pivots over
to the copy, or a call without I<--pivot> leaves the destination as a
faithful copy of that point in time. However, if I<--wait> is specified,
then this command will block until the mirroring phase begins, or cancel
the operation if the optional I<timeout> in seconds elapses or SIGINT is
sent (usually with C<Ctrl-C>). Using I<--verbose> along with I<--wait>
will produce periodic status updates. Using I<--pivot> (similar to
B<blockjob> I<--pivot>) or I<--finish> (similar to B<blockjob> I<--abort>)
implies I<--wait>, and will additionally end the job cleanly rather than
leaving things in the mirroring phase. If job cancellation is triggered
by timeout or by I<--finish>, I<--async> will return control to the user
as fast as possible, otherwise the command may continue to block a little
while longer until the job has actually cancelled.
I<path> specifies fully-qualified path of the disk.
I<bandwidth> specifies copying bandwidth limit in MiB/s. Specifying a negative
value is interpreted as an unsigned long long value that might be essentially
unlimited, but more likely would overflow; it is safer to use 0 for that
purpose. Specifying I<granularity> allows fine-tuning of the granularity that
will be copied when a dirty region is detected; larger values trigger less
I/O overhead but may end up copying more data overall (the default value is
usually correct); this value must be a power of two. Specifying I<buf-size>
will control how much data can be simultaneously in-flight during the copy;
larger values use more memory but may allow faster completion (the default
value is usually correct).
=item B<blockpull> I<domain> I<path> [I<bandwidth>] [I<base>]
[I<--wait> [I<--verbose>] [I<--timeout> B<seconds>] [I<--async>]]
[I<--keep-relative>]
Populate a disk from its backing image chain. By default, this command
flattens the entire chain; but if I<base> is specified, containing the
name of one of the backing files in the chain, then that file becomes
the new backing file and only the intermediate portion of the chain is
pulled. Once all requested data from the backing image chain has been
pulled, the disk no longer depends on that portion of the backing chain.
By default, this command returns as soon as possible, and data for
the entire disk is pulled in the background; the progress of the
operation can be checked with B<blockjob>. However, if I<--wait> is
specified, then this command will block until the operation completes,
or cancel the operation if the optional I<timeout> in seconds elapses
or SIGINT is sent (usually with C<Ctrl-C>). Using I<--verbose> along
with I<--wait> will produce periodic status updates. If job cancellation
is triggered, I<--async> will return control to the user as fast as
possible, otherwise the command may continue to block a little while
longer until the job is done cleaning up.
Using the I<--keep-relative> flag will keep the backing chain names
relative.
I<path> specifies fully-qualified path of the disk; it corresponds
to a unique target name (<target dev='name'/>) or source file (<source
file='name'/>) for one of the disk devices attached to I<domain> (see
also B<domblklist> for listing these names).
I<bandwidth> specifies copying bandwidth limit in MiB/s. Specifying a negative
value is interpreted as an unsigned long long value or essentially
unlimited. The hypervisor can choose whether to reject the value or
convert it to the maximum value allowed.
=item B<blkdeviotune> I<domain> I<device>
[[I<--config>] [I<--live>] | [I<--current>]]
[[I<total-bytes-sec>] | [I<read-bytes-sec>] [I<write-bytes-sec>]]
[[I<total-iops-sec>] | [I<read-iops-sec>] [I<write-iops-sec>]]
Set or query the block disk io parameters for a block device of I<domain>.
I<device> specifies a unique target name (<target dev='name'/>) or source
file (<source file='name'/>) for one of the disk devices attached to
I<domain> (see also B<domblklist> for listing these names).
If no limit is specified, it will query current I/O limits setting.
Otherwise, alter the limits with these flags:
I<--total-bytes-sec> specifies total throughput limit in bytes per second.
I<--read-bytes-sec> specifies read throughput limit in bytes per second.
I<--write-bytes-sec> specifies write throughput limit in bytes per second.
I<--total-iops-sec> specifies total I/O operations limit per second.
I<--read-iops-sec> specifies read I/O operations limit per second.
I<--write-iops-sec> specifies write I/O operations limit per second.
Older versions of virsh only accepted these options with underscore
instead of dash, as in I<--total_bytes_sec>.
Bytes and iops values are independent, but setting only one value (such
as --read-bytes-sec) resets the other two in that category to unlimited.
An explicit 0 also clears any limit. A non-zero value for a given total
cannot be mixed with non-zero values for read or write.
If I<--live> is specified, affect a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--current> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on hypervisor.
=item B<blockjob> I<domain> I<path> { [I<--abort>] [I<--async>] [I<--pivot>] |
[I<--info>] [I<--raw>] [I<--bytes>] | [I<bandwidth>] }
Manage active block operations. There are three mutually-exclusive modes:
I<--info>, I<bandwidth>, and I<--abort>. I<--async> and I<--pivot> imply
abort mode; I<--raw> implies info mode; and if no mode was given, I<--info>
mode is assumed.
I<path> specifies fully-qualified path of the disk; it corresponds
to a unique target name (<target dev='name'/>) or source file (<source
file='name'/>) for one of the disk devices attached to I<domain> (see
also B<domblklist> for listing these names).
In I<--abort> mode, the active job on the specified disk will
be aborted. If I<--async> is also specified, this command will return
immediately, rather than waiting for the cancellation to complete. If
I<--pivot> is specified, this requests that an active copy or active
commit job be pivoted over to the new image.
In I<--info> mode, the active job information on the specified
disk will be printed. By default, the output is a single human-readable
summary line; this format may change in future versions. Adding
I<--raw> lists each field of the struct, in a stable format. If the
I<--bytes> flag is set, then the command errors out if the server could
not supply bytes/s resolution; when omitting the flag, raw output is
listed in MiB/s and human-readable output automatically selects the
best resolution supported by the server.
I<bandwidth> can be used to set bandwidth limit for the active job.
Specifying a negative value is interpreted as an unsigned long long
value or essentially unlimited. The hypervisor can choose whether to
reject the value or convert it to the maximum value allowed.
=item B<blockresize> I<domain> I<path> I<size>
Resize a block device of domain while the domain is running, I<path>
specifies the absolute path of the block device; it corresponds
to a unique target name (<target dev='name'/>) or source file (<source
file='name'/>) for one of the disk devices attached to I<domain> (see
also B<domblklist> for listing these names).
I<size> is a scaled integer (see B<NOTES> above) which defaults to KiB
(blocks of 1024 bytes) if there is no suffix. You must use a suffix of
"B" to get bytes (note that for historical reasons, this differs from
B<vol-resize> which defaults to bytes without a suffix).
=item B<domdisplay> I<domain> [I<--include-password>]
Output a URI which can be used to connect to the graphical display of the
domain via VNC, SPICE or RDP. If I<--include-password> is specified, the
SPICE channel password will be included in the URI.
=item B<domfsfreeze> I<domain> [[I<--mountpoint>] B<mountpoint>...]
Freeze mounted filesystems within a running domain to prepare for consistent
snapshots.
The I<--mountpoint> option takes a parameter B<mountpoint>, which is a
mount point path of the filesystem to be frozen. This option can occur
multiple times. If this is not specified, every mounted filesystem is frozen.
Note: B<snapshot-create> command has a I<--quiesce> option to freeze
and thaw the filesystems automatically to keep snapshots consistent.
B<domfsfreeze> command is only needed when a user wants to utilize the
native snapshot features of storage devices not supported by libvirt.
=item B<domfsthaw> I<domain> [[I<--mountpoint>] B<mountpoint>...]
Thaw mounted filesystems within a running domain, which have been frozen by
domfsfreeze command.
The I<--mountpoint> option takes a parameter B<mountpoint>, which is a
mount point path of the filesystem to be thawed. This option can occur
multiple times. If this is not specified, every mounted filesystem is thawed.
=item B<domfstrim> I<domain> [I<--minimum> B<bytes>]
[I<--mountpoint mountPoint>]
Issue a fstrim command on all mounted filesystems within a running
domain. It discards blocks which are not in use by the filesystem.
If I<--minimum> B<bytes> is specified, it tells guest kernel length
of contiguous free range. Smaller than this may be ignored (this is
a hint and the guest may not respect it). By increasing this value,
the fstrim operation will complete more quickly for filesystems
with badly fragmented free space, although not all blocks will
be discarded. The default value is zero, meaning "discard
every free block". Moreover, a if user wants to trim only one mount
point, it can be specified via optional I<--mountpoint> parameter.
=item B<domhostname> I<domain>
Returns the hostname of a domain, if the hypervisor makes it available.
=item B<dominfo> I<domain>
Returns basic information about the domain.
=item B<domuuid> I<domain-name-or-id>
Convert a domain name or id to domain UUID
=item B<domid> I<domain-name-or-uuid>
Convert a domain name (or UUID) to a domain id
=item B<domjobabort> I<domain>
Abort the currently running domain job.
=item B<domjobinfo> I<domain> [I<--completed>]
Returns information about jobs running on a domain. I<--completed> tells
virsh to return information about a recently finished job. Statistics of
a completed job are automatically destroyed once read or when libvirtd
is restarted. Note that time information returned for completed
migrations may be completely irrelevant unless both source and
destination hosts have synchronized time (i.e., NTP daemon is running
on both of them).
=item B<domname> I<domain-id-or-uuid>
Convert a domain Id (or UUID) to domain name
=item B<domstate> I<domain> [I<--reason>]
Returns state about a domain. I<--reason> tells virsh to also print
reason for the state.
=item B<domcontrol> I<domain>
Returns state of an interface to VMM used to control a domain. For
states other than "ok" or "error" the command also prints number of
seconds elapsed since the control interface entered its current state.
=item B<domtime> I<domain> { [I<--now>] [I<--pretty>] [I<--sync>]
[I<--time> B<time>] }
Gets or sets the domain's system time. When run without any arguments
(but I<domain>), the current domain's system time is printed out. The
I<--pretty> modifier can be used to print the time in more human
readable form.
When I<--time> B<time> is specified, the domain's time is
not gotten but set instead. The I<--now> modifier acts like if it was
an alias for I<--time> B<$now>, which means it sets the time that is
currently on the host virsh is running at. In both cases (setting and
getting), time is in seconds relative to Epoch of 1970-01-01 in UTC.
The I<--sync> modifies the set behavior a bit: The time passed is
ignored, but the time to set is read from domain's RTC instead. Please
note, that some hypervisors may require a guest agent to be configured
in order to get or set the guest time.
=item B<domxml-from-native> I<format> I<config>
Convert the file I<config> in the native guest configuration format
named by I<format> to a domain XML format. For QEMU/KVM hypervisor,
the I<format> argument must be B<qemu-argv>. For Xen hypervisor, the
I<format> argument may be B<xen-xm> or B<xen-sxpr>. For LXC hypervisor,
the I<format> argument must be B<lxc-tools>.
=item B<domxml-to-native> I<format> I<xml>
Convert the file I<xml> in domain XML format to the native guest
configuration format named by I<format>. For QEMU/KVM hypervisor,
the I<format> argument must be B<qemu-argv>. For Xen hypervisor, the
I<format> argument may be B<xen-xm> or B<xen-sxpr>. For LXC hypervisor,
the I<format> argument must be B<lxc-tools>.
=item B<dump> I<domain> I<corefilepath> [I<--bypass-cache>]
{ [I<--live>] | [I<--crash>] | [I<--reset>] } [I<--verbose>] [I<--memory-only>]
[I<--format> I<string>]
Dumps the core of a domain to a file for analysis.
If I<--live> is specified, the domain continues to run until the core
dump is complete, rather than pausing up front.
If I<--crash> is specified, the domain is halted with a crashed status,
rather than merely left in a paused state.
If I<--reset> is specified, the domain is reset after successful dump.
Note, these three switches are mutually exclusive.
If I<--bypass-cache> is specified, the save will avoid the file system
cache, although this may slow down the operation.
If I<--memory-only> is specified, the file is elf file, and will only
include domain's memory and cpu common register value. It is very
useful if the domain uses host devices directly.
I<--format> I<string> is used to specify the format of 'memory-only'
dump, and I<string> can be one of them: elf, kdump-zlib(kdump-compressed
format with zlib-compressed), kdump-lzo(kdump-compressed format with
lzo-compressed), kdump-snappy(kdump-compressed format with snappy-compressed).
The progress may be monitored using B<domjobinfo> virsh command and canceled
with B<domjobabort> command (sent by another virsh instance). Another option
is to send SIGINT (usually with C<Ctrl-C>) to the virsh process running
B<dump> command. I<--verbose> displays the progress of dump.
NOTE: Some hypervisors may require the user to manually ensure proper
permissions on file and path specified by argument I<corefilepath>.
=item B<dumpxml> I<domain> [I<--inactive>] [I<--security-info>]
[I<--update-cpu>] [I<--migratable>]
Output the domain information as an XML dump to stdout, this format can be used
by the B<create> command. Additional options affecting the XML dump may be
used. I<--inactive> tells virsh to dump domain configuration that will be used
on next start of the domain as opposed to the current domain configuration.
Using I<--security-info> will also include security sensitive information
in the XML dump. I<--update-cpu> updates domain CPU requirements according to
host CPU. With I<--migratable> one can request an XML that is suitable for
migrations, i.e., compatible with older libvirt releases and possibly amended
with internal run-time options. This option may automatically enable other
options (I<--update-cpu>, I<--security-info>, ...) as necessary.
=item B<edit> I<domain>
Edit the XML configuration file for a domain, which will affect the
next boot of the guest.
This is equivalent to:
virsh dumpxml --inactive --security-info domain > domain.xml
vi domain.xml (or make changes with your other text editor)
virsh define domain.xml
except that it does some error checking.
The editor used can be supplied by the C<$VISUAL> or C<$EDITOR> environment
variables, and defaults to C<vi>.
=item B<event> {[I<domain>] { I<event> | I<--all> } [I<--loop>]
[I<--timeout> I<seconds>] | I<--list>}
Wait for a class of domain events to occur, and print appropriate details
of events as they happen. The events can optionally be filtered by
I<domain>. Using I<--list> as the only argument will provide a list
of possible I<event> values known by this client, although the connection
might not allow registering for all these events. It is also possible
to use I<--all> instead of I<event> to register for all possible event
types at once.
By default, this command is one-shot, and returns success once an event
occurs; you can send SIGINT (usually via C<Ctrl-C>) to quit immediately.
If I<--timeout> is specified, the command gives up waiting for events
after I<seconds> have elapsed. With I<--loop>, the command prints all
events until a timeout or interrupt key.
=item B<managedsave> I<domain> [I<--bypass-cache>]
[{I<--running> | I<--paused>}] [I<--verbose>]
Save and destroy (stop) a running domain, so it can be restarted from the same
state at a later time. When the virsh B<start> command is next run for
the domain, it will automatically be started from this saved state.
If I<--bypass-cache> is specified, the save will avoid the file system
cache, although this may slow down the operation.
The progress may be monitored using B<domjobinfo> virsh command and canceled
with B<domjobabort> command (sent by another virsh instance). Another option
is to send SIGINT (usually with C<Ctrl-C>) to the virsh process running
B<managedsave> command. I<--verbose> displays the progress of save.
Normally, starting a managed save will decide between running or paused
based on the state the domain was in when the save was done; passing
either the I<--running> or I<--paused> flag will allow overriding which
state the B<start> should use.
The B<dominfo> command can be used to query whether a domain currently
has any managed save image.
=item B<managedsave-remove> I<domain>
Remove the B<managedsave> state file for a domain, if it exists. This
ensures the domain will do a full boot the next time it is started.
=item B<maxvcpus> [I<type>]
Provide the maximum number of virtual CPUs supported for a guest VM on
this connection. If provided, the I<type> parameter must be a valid
type attribute for the <domain> element of XML.
=item B<cpu-stats> I<domain> [I<--total>] [I<start>] [I<count>]
Provide cpu statistics information of a domain. The domain should
be running. Default it shows stats for all CPUs, and a total. Use
I<--total> for only the total stats, I<start> for only the per-cpu
stats of the CPUs from I<start>, I<count> for only I<count> CPUs'
stats.
=item B<metadata> I<domain> [[I<--live>] [I<--config>] | [I<--current>]]
[I<--edit>] [I<uri>] [I<key>] [I<set>] [I<--remove>]
Show or modify custom XML metadata of a domain. The metadata is a user
defined XML that allows to store arbitrary XML data in the domain definition.
Multiple separate custom metadata pieces can be stored in the domain XML.
The pieces are identified by a private XML namespace provided via the
I<uri> argument. (See also B<desc> that works with textual metadata of
a domain.)
Flags I<--live> or I<--config> select whether this command works on live
or persistent definitions of the domain. If both I<--live> and I<--config>
are specified, the I<--config> option takes precedence on getting the current
description and both live configuration and config are updated while setting
the description. I<--current> is exclusive and implied if none of these was
specified.
Flag I<--remove> specifies that the metadata element specified by the I<uri>
argument should be removed rather than updated.
Flag I<--edit> specifies that an editor with the metadata identified by the
I<uri> argument should be opened and the contents saved back afterwards.
Otherwise the new contents can be provided via the I<set> argument.
When setting metadata via I<--edit> or I<set> the I<key> argument must be
specified and is used to prefix the custom elements to bind them
to the private namespace.
If neither of I<--edit> and I<set> are specified the XML metadata corresponding
to the I<uri> namespace is displayed instead of being modified.
=item B<migrate> [I<--live>] [I<--offline>] [I<--direct>] [I<--p2p> [I<--tunnelled>]]
[I<--persistent>] [I<--undefinesource>] [I<--suspend>] [I<--copy-storage-all>]
[I<--copy-storage-inc>] [I<--change-protection>] [I<--unsafe>] [I<--verbose>]
[I<--compressed>] [I<--abort-on-error>] [I<--auto-converge>]
I<domain> I<desturi> [I<migrateuri>] [I<graphicsuri>] [I<listen-address>]
[I<dname>] [I<--timeout> B<seconds>] [I<--xml> B<file>]
Migrate domain to another host. Add I<--live> for live migration; <--p2p>
for peer-2-peer migration; I<--direct> for direct migration; or I<--tunnelled>
for tunnelled migration. I<--offline> migrates domain definition without
starting the domain on destination and without stopping it on source host.
Offline migration may be used with inactive domains and it must be used with
I<--persistent> option. I<--persistent> leaves the domain persistent on
destination host, I<--undefinesource> undefines the domain on the source host,
and I<--suspend> leaves the domain paused on the destination host.
I<--copy-storage-all> indicates migration with non-shared storage with full
disk copy, I<--copy-storage-inc> indicates migration with non-shared storage
with incremental copy (same base image shared between source and destination).
In both cases the disk images have to exist on destination host, the
I<--copy-storage-...> options only tell libvirt to transfer data from the
images on source host to the images found at the same place on the destination
host. I<--change-protection> enforces that no incompatible configuration
changes will be made to the domain while the migration is underway; this flag
is implicitly enabled when supported by the hypervisor, but can be explicitly
used to reject the migration if the hypervisor lacks change protection
support. I<--verbose> displays the progress of migration. I<--compressed>
activates compression of memory pages that have to be transferred repeatedly
during live migration. I<--abort-on-error> cancels the migration if a soft
error (for example I/O error) happens during the migration. I<--auto-converge>
forces convergence during live migration.
B<Note>: Individual hypervisors usually do not support all possible types of
migration. For example, QEMU does not support direct migration.
In some cases libvirt may refuse to migrate the domain because doing so may
lead to potential problems such as data corruption, and thus the migration is
considered unsafe. For QEMU domain, this may happen if the domain uses disks
without explicitly setting cache mode to "none". Migrating such domains is
unsafe unless the disk images are stored on coherent clustered filesystem,
such as GFS2 or GPFS. If you are sure the migration is safe or you just do not
care, use I<--unsafe> to force the migration.
I<dname> is used for renaming the domain to new name during migration, which
also usually can be omitted. Likewise, I<--xml> B<file> is usually
omitted, but can be used to supply an alternative XML file for use on
the destination to supply a larger set of changes to any host-specific
portions of the domain XML, such as accounting for naming differences
between source and destination in accessing underlying storage.
I<--timeout> B<seconds> forces guest to suspend when live migration exceeds
that many seconds, and
then the migration will complete offline. It can only be used with I<--live>.
Running migration can be canceled by interrupting virsh (usually using
C<Ctrl-C>) or by B<domjobabort> command sent from another virsh instance.
The I<desturi> and I<migrateuri> parameters can be used to control which
destination the migration uses. I<desturi> is important for managed
migration, but unused for direct migration; I<migrateuri> is required
for direct migration, but can usually be automatically determined for
managed migration.
B<Note>: The I<desturi> parameter for normal migration and peer2peer migration
has different semantics:
=over 4
=item * normal migration: the I<desturi> is an address of the target host as
seen from the client machine.
=item * peer2peer migration: the I<desturi> is an address of the target host as
seen from the source machine.
=back
When I<migrateuri> is not specified, libvirt will automatically determine the
hypervisor specific URI. Some hypervisors, including QEMU, have an optional
"migration_host" configuration parameter (useful when the host has multiple
network interfaces). If this is unspecified, libvirt determines a name
by looking up the target host's configured hostname.
There are a few scenarios where specifying I<migrateuri> may help:
=over 4
=item * The configured hostname is incorrect, or DNS is broken. If a host has a
hostname which will not resolve to match one of its public IP addresses, then
libvirt will generate an incorrect URI. In this case I<migrateuri> should be
explicitly specified, using an IP address, or a correct hostname.
=item * The host has multiple network interfaces. If a host has multiple network
interfaces, it might be desirable for the migration data stream to be sent over
a specific interface for either security or performance reasons. In this case
I<migrateuri> should be explicitly specified, using an IP address associated
with the network to be used.
=item * The firewall restricts what ports are available. When libvirt generates
a migration URI, it will pick a port number using hypervisor specific rules.
Some hypervisors only require a single port to be open in the firewalls, while
others require a whole range of port numbers. In the latter case I<migrateuri>
might be specified to choose a specific port number outside the default range in
order to comply with local firewall policies.
=back
See L<http://libvirt.org/migration.html#uris> for more details on
migration URIs.
Optional I<graphicsuri> overrides connection parameters used for automatically
reconnecting a graphical clients at the end of migration. If omitted, libvirt
will compute the parameters based on target host IP address. In case the
client does not have a direct access to the network virtualization hosts are
connected to and needs to connect through a proxy, I<graphicsuri> may be used
to specify the address the client should connect to. The URI is formed as
follows:
protocol://hostname[:port]/[?parameters]
where protocol is either "spice" or "vnc" and parameters is a list of protocol
specific parameters separated by '&'. Currently recognized parameters are
"tlsPort" and "tlsSubject". For example,
spice://target.host.com:1234/?tlsPort=4567
Optional I<listen-address> sets the listen address that hypervisor on the
destination side should bind to for incoming migration. Both IPv4 and IPv6
addresses are accepted as well as hostnames (the resolving is done on
destination). Some hypervisors do not support this feature and will return an
error if this parameter is used.
=item B<migrate-setmaxdowntime> I<domain> I<downtime>
Set maximum tolerable downtime for a domain which is being live-migrated to
another host. The I<downtime> is a number of milliseconds the guest is allowed
to be down at the end of live migration.
=item B<migrate-compcache> I<domain> [I<--size> B<bytes>]
Sets and/or gets size of the cache (in bytes) used for compressing repeatedly
transferred memory pages during live migration. When called without I<size>,
the command just prints current size of the compression cache. When I<size>
is specified, the hypervisor is asked to change compression cache to I<size>
bytes and then the current size is printed (the result may differ from the
requested size due to rounding done by the hypervisor). The I<size> option
is supposed to be used while the domain is being live-migrated as a reaction
to migration progress and increasing number of compression cache misses
obtained from domjobinfo.
=item B<migrate-setspeed> I<domain> I<bandwidth>
Set the maximum migration bandwidth (in MiB/s) for a domain which is being
migrated to another host. I<bandwidth> is interpreted as an unsigned long
long value. Specifying a negative value results in an essentially unlimited
value being provided to the hypervisor. The hypervisor can choose whether to
reject the value or convert it to the maximum value allowed.
=item B<migrate-getspeed> I<domain>
Get the maximum migration bandwidth (in MiB/s) for a domain.
=item B<numatune> I<domain> [I<--mode> B<mode>] [I<--nodeset> B<nodeset>]
[[I<--config>] [I<--live>] | [I<--current>]]
Set or get a domain's numa parameters, corresponding to the <numatune>
element of domain XML. Without flags, the current settings are
displayed.
I<mode> can be one of `strict', `interleave' and `preferred' or any
valid number from the virDomainNumatuneMemMode enum in case the daemon
supports it. For a running domain, the mode can't be changed, and the
nodeset can be changed only if the domain was started with a mode of
`strict'.
I<nodeset> is a list of numa nodes used by the host for running the domain.
Its syntax is a comma separated list, with '-' for ranges and '^' for
excluding a node.
If I<--live> is specified, set scheduler information of a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
=item B<reboot> I<domain> [I<--mode MODE-LIST>]
Reboot a domain. This acts just as if the domain had the B<reboot>
command run from the console. The command returns as soon as it has
executed the reboot action, which may be significantly before the
domain actually reboots.
The exact behavior of a domain when it reboots is set by the
I<on_reboot> parameter in the domain's XML definition.
By default the hypervisor will try to pick a suitable shutdown
method. To specify an alternative method, the I<--mode> parameter
can specify a comma separated list which includes C<acpi>, C<agent>,
C<initctl>, C<signal> and C<paravirt>. The order in which drivers will
try each mode is undefined, and not related to the order specified to virsh.
For strict control over ordering, use a single mode at a time and
repeat the command.
=item B<reset> I<domain>
Reset a domain immediately without any guest shutdown. B<reset>
emulates the power reset button on a machine, where all guest
hardware sees the RST line set and reinitializes internal state.
B<Note>: Reset without any guest OS shutdown risks data loss.
=item B<restore> I<state-file> [I<--bypass-cache>] [I<--xml> B<file>]
[{I<--running> | I<--paused>}]
Restores a domain from a B<virsh save> state file. See I<save> for more info.
If I<--bypass-cache> is specified, the restore will avoid the file system
cache, although this may slow down the operation.
I<--xml> B<file> is usually omitted, but can be used to supply an
alternative XML file for use on the restored guest with changes only
in the host-specific portions of the domain XML. For example, it can
be used to account for file naming differences in underlying storage
due to disk snapshots taken after the guest was saved.
Normally, restoring a saved image will use the state recorded in the
save image to decide between running or paused; passing either the
I<--running> or I<--paused> flag will allow overriding which state the
domain should be started in.
B<Note>: To avoid corrupting file system contents within the domain, you
should not reuse the saved state file for a second B<restore> unless you
have also reverted all storage volumes back to the same contents as when
the state file was created.
=item B<save> I<domain> I<state-file> [I<--bypass-cache>] [I<--xml> B<file>]
[{I<--running> | I<--paused>}] [I<--verbose>]
Saves a running domain (RAM, but not disk state) to a state file so that
it can be restored
later. Once saved, the domain will no longer be running on the
system, thus the memory allocated for the domain will be free for
other domains to use. B<virsh restore> restores from this state file.
If I<--bypass-cache> is specified, the save will avoid the file system
cache, although this may slow down the operation.
The progress may be monitored using B<domjobinfo> virsh command and canceled
with B<domjobabort> command (sent by another virsh instance). Another option
is to send SIGINT (usually with C<Ctrl-C>) to the virsh process running
B<save> command. I<--verbose> displays the progress of save.
This is roughly equivalent to doing a hibernate on a running computer,
with all the same limitations. Open network connections may be
severed upon restore, as TCP timeouts may have expired.
I<--xml> B<file> is usually omitted, but can be used to supply an
alternative XML file for use on the restored guest with changes only
in the host-specific portions of the domain XML. For example, it can
be used to account for file naming differences that are planned to
be made via disk snapshots of underlying storage after the guest is saved.
Normally, restoring a saved image will decide between running or paused
based on the state the domain was in when the save was done; passing
either the I<--running> or I<--paused> flag will allow overriding which
state the B<restore> should use.
Domain saved state files assume that disk images will be unchanged
between the creation and restore point. For a more complete system
restore point, where the disk state is saved alongside the memory
state, see the B<snapshot> family of commands.
=item B<save-image-define> I<file> I<xml> [{I<--running> | I<--paused>}]
Update the domain XML that will be used when I<file> is later
used in the B<restore> command. The I<xml> argument must be a file
name containing the alternative XML, with changes only in the
host-specific portions of the domain XML. For example, it can
be used to account for file naming differences resulting from creating
disk snapshots of underlying storage after the guest was saved.
The save image records whether the domain should be restored to a
running or paused state. Normally, this command does not alter the
recorded state; passing either the I<--running> or I<--paused> flag
will allow overriding which state the B<restore> should use.
=item B<save-image-dumpxml> I<file> [I<--security-info>]
Extract the domain XML that was in effect at the time the saved state
file I<file> was created with the B<save> command. Using
I<--security-info> will also include security sensitive information.
=item B<save-image-edit> I<file> [{I<--running> | I<--paused>}]
Edit the XML configuration associated with a saved state file I<file>
created by the B<save> command.
The save image records whether the domain should be restored to a
running or paused state. Normally, this command does not alter the
recorded state; passing either the I<--running> or I<--paused> flag
will allow overriding which state the B<restore> should use.
This is equivalent to:
virsh save-image-dumpxml state-file > state-file.xml
vi state-file.xml (or make changes with your other text editor)
virsh save-image-define state-file state-file-xml
except that it does some error checking.
The editor used can be supplied by the C<$VISUAL> or C<$EDITOR> environment
variables, and defaults to C<vi>.
=item B<schedinfo> I<domain> [[I<--config>] [I<--live>] | [I<--current>]]
[[I<--set>] B<parameter=value>]...
=item B<schedinfo> [I<--weight> B<number>] [I<--cap> B<number>]
I<domain>
Allows you to show (and set) the domain scheduler parameters. The parameters
available for each hypervisor are:
LXC (posix scheduler) : cpu_shares, vcpu_period, vcpu_quota
QEMU/KVM (posix scheduler): cpu_shares, vcpu_period, vcpu_quota,
emulator_period, emulator_quota
Xen (credit scheduler): weight, cap
ESX (allocation scheduler): reservation, limit, shares
If I<--live> is specified, set scheduler information of a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
B<Note>: The cpu_shares parameter has a valid value range of 0-262144; Negative
values are wrapped to positive, and larger values are capped at the maximum.
Therefore, -1 is a useful shorthand for 262144. On the Linux kernel, the
values 0 and 1 are automatically converted to a minimal value of 2.
B<Note>: The weight and cap parameters are defined only for the
XEN_CREDIT scheduler and are now I<DEPRECATED>.
B<Note>: The vcpu_period/emulator_period parameters have a valid value range
of 1000-1000000 or 0, and the vcpu_quota/emulator_quota parameters have a
valid value range of 1000-18446744073709551 or less than 0. The value 0 for
either parameter is the same as not specifying that parameter.
=item B<screenshot> I<domain> [I<imagefilepath>] [I<--screen> B<screenID>]
Takes a screenshot of a current domain console and stores it into a file.
Optionally, if hypervisor supports more displays for a domain, I<screenID>
allows to specify which screen will be captured. It is the sequential number
of screen. In case of multiple graphics cards, heads are enumerated before
devices, e.g. having two graphics cards, both with four heads, screen ID 5
addresses the second head on the second card.
=item B<send-key> I<domain> [I<--codeset> B<codeset>]
[I<--holdtime> B<holdtime>] I<keycode>...
Parse the I<keycode> sequence as keystrokes to send to I<domain>.
Each I<keycode> can either be a numeric value or a symbolic name from
the corresponding codeset. If I<--holdtime> is given, each keystroke
will be held for that many milliseconds. The default codeset is
B<linux>, but use of the I<--codeset> option allows other codesets to
be chosen.
If multiple keycodes are specified, they are all sent simultaneously
to the guest, and they may be received in random order. If you need
distinct keypresses, you must use multiple send-key invocations.
=over 4
=item B<linux>
The numeric values are those defined by the Linux generic input
event subsystem. The symbolic names match the corresponding
Linux key constant macro names.
=item B<xt>
The numeric values are those defined by the original XT keyboard
controller. No symbolic names are provided
=item B<atset1>
The numeric values are those defined by the AT keyboard controller,
set 1 (aka XT compatible set). Extended keycoes from B<atset1>
may differ from extended keycodes in the B<xt> codeset. No symbolic
names are provided
=item B<atset2>
The numeric values are those defined by the AT keyboard controller,
set 2. No symbolic names are provided
=item B<atset3>
The numeric values are those defined by the AT keyboard controller,
set 3 (aka PS/2 compatible set). No symbolic names are provided
=item B<os_x>
The numeric values are those defined by the OS-X keyboard input
subsystem. The symbolic names match the corresponding OS-X key
constant macro names
=item B<xt_kbd>
The numeric values are those defined by the Linux KBD device.
These are a variant on the original XT codeset, but often with
different encoding for extended keycodes. No symbolic names are
provided.
=item B<win32>
The numeric values are those defined by the Win32 keyboard input
subsystem. The symbolic names match the corresponding Win32 key
constant macro names
=item B<usb>
The numeric values are those defined by the USB HID specification
for keyboard input. No symbolic names are provided
=item B<rfb>
The numeric values are those defined by the RFB extension for sending
raw keycodes. These are a variant on the XT codeset, but extended
keycodes have the low bit of the second byte set, instead of the high
bit of the first byte. No symbolic names are provided.
=back
B<Examples>
# send three strokes 'k', 'e', 'y', using xt codeset. these
# are all pressed simultaneously and may be received by the guest
# in random order
virsh send-key dom --codeset xt 37 18 21
# send one stroke 'right-ctrl+C'
virsh send-key dom KEY_RIGHTCTRL KEY_C
# send a tab, held for 1 second
virsh send-key --holdtime 1000 0xf
=item B<send-process-signal> I<domain-id> I<pid> I<signame>
Send a signal I<signame> to the process identified by I<pid> running in
the virtual domain I<domain-id>. The I<pid> is a process ID in the virtual
domain namespace.
The I<signame> argument may be either an integer signal constant number,
or one of the symbolic names:
"nop", "hup", "int", "quit", "ill",
"trap", "abrt", "bus", "fpe", "kill",
"usr1", "segv", "usr2", "pipe", "alrm",
"term", "stkflt", "chld", "cont", "stop",
"tstp", "ttin", "ttou", "urg", "xcpu",
"xfsz", "vtalrm", "prof", "winch", "poll",
"pwr", "sys", "rt0", "rt1", "rt2", "rt3",
"rt4", "rt5", "rt6", "rt7", "rt8", "rt9",
"rt10", "rt11", "rt12", "rt13", "rt14", "rt15",
"rt16", "rt17", "rt18", "rt19", "rt20", "rt21",
"rt22", "rt23", "rt24", "rt25", "rt26", "rt27",
"rt28", "rt29", "rt30", "rt31", "rt32"
The symbol name may optionally be prefixed with 'sig' or 'sig_' and
may be in uppercase or lowercase.
B<Examples>
virsh send-process-signal myguest 1 15
virsh send-process-signal myguest 1 term
virsh send-process-signal myguest 1 sigterm
virsh send-process-signal myguest 1 SIG_HUP
=item B<setmem> I<domain> B<size> [[I<--config>] [I<--live>] |
[I<--current>]]
Change the memory allocation for a guest domain.
If I<--live> is specified, perform a memory balloon of a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on hypervisor.
I<size> is a scaled integer (see B<NOTES> above); it defaults to kibibytes
(blocks of 1024 bytes) unless you provide a suffix (and the older option
name I<--kilobytes> is available as a deprecated synonym) . Libvirt rounds
up to the nearest kibibyte. Some hypervisors require a larger granularity
than KiB, and requests that are not an even multiple will be rounded up.
For example, vSphere/ESX rounds the parameter up to mebibytes (1024 kibibytes).
For Xen, you can only adjust the memory of a running domain if the domain is
paravirtualized or running the PV balloon driver.
=item B<setmaxmem> I<domain> B<size> [[I<--config>] [I<--live>] |
[I<--current>]]
Change the maximum memory allocation limit for a guest domain.
If I<--live> is specified, affect a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on hypervisor.
Some hypervisors such as QEMU/KVM don't support live changes (especially
increasing) of the maximum memory limit.
I<size> is a scaled integer (see B<NOTES> above); it defaults to kibibytes
(blocks of 1024 bytes) unless you provide a suffix (and the older option
name I<--kilobytes> is available as a deprecated synonym) . Libvirt rounds
up to the nearest kibibyte. Some hypervisors require a larger granularity
than KiB, and requests that are not an even multiple will be rounded up.
For example, vSphere/ESX rounds the parameter up to mebibytes (1024 kibibytes).
=item B<memtune> I<domain> [I<--hard-limit> B<size>]
[I<--soft-limit> B<size>] [I<--swap-hard-limit> B<size>]
[I<--min-guarantee> B<size>] [[I<--config>] [I<--live>] | [I<--current>]]
Allows you to display or set the domain memory parameters. Without
flags, the current settings are displayed; with a flag, the
appropriate limit is adjusted if supported by the hypervisor. LXC and
QEMU/KVM support I<--hard-limit>, I<--soft-limit>, and I<--swap-hard-limit>.
I<--min-guarantee> is supported only by ESX hypervisor. Each of these
limits are scaled integers (see B<NOTES> above), with a default of
kibibytes (blocks of 1024 bytes) if no suffix is present. Libvirt rounds
up to the nearest kibibyte. Some hypervisors require a larger granularity
than KiB, and requests that are not an even multiple will be rounded up.
For example, vSphere/ESX rounds the parameter up to mebibytes (1024 kibibytes).
If I<--live> is specified, affect a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on hypervisor.
For QEMU/KVM, the parameters are applied to the QEMU process as a whole.
Thus, when counting them, one needs to add up guest RAM, guest video RAM, and
some memory overhead of QEMU itself. The last piece is hard to determine so
one needs guess and try.
=over 4
=item I<--hard-limit>
The maximum memory the guest can use.
=item I<--soft-limit>
The memory limit to enforce during memory contention.
=item I<--swap-hard-limit>
The maximum memory plus swap the guest can use. This has to be more
than hard-limit value provided.
=item I<--min-guarantee>
The guaranteed minimum memory allocation for the guest.
=back
Specifying -1 as a value for these limits is interpreted as unlimited.
=item B<blkiotune> I<domain> [I<--weight> B<weight>]
[I<--device-weights> B<device-weights>]
[I<--device-read-iops-sec> B<device-read-iops-sec>]
[I<--device-write-iops-sec> B<device-write-iops-sec>]
[I<--device-read-bytes-sec> B<device-read-bytes-sec>]
[I<--device-write-bytes-sec> B<device-write-bytes-sec>]
[[I<--config>] [I<--live>] | [I<--current>]]
Display or set the blkio parameters. QEMU/KVM supports I<--weight>.
I<--weight> is in range [100, 1000]. After kernel 2.6.39, the value
could be in the range [10, 1000].
B<device-weights> is a single string listing one or more device/weight
pairs, in the format of /path/to/device,weight,/path/to/device,weight.
Each weight is in the range [100, 1000], [10, 1000] after kernel 2.6.39,
or the value 0 to remove that device from per-device listings.
Only the devices listed in the string are modified;
any existing per-device weights for other devices remain unchanged.
B<device-read-iops-sec> is a single string listing one or more device/read_iops_sec
pairs, int the format of /path/to/device,read_iops_sec,/path/to/device,read_iops_sec.
Each read_iops_sec is a number which type is unsigned int, value 0 to remove that
device from per-decice listing.
Only the devices listed in the string are modified;
any existing per-device read_iops_sec for other devices remain unchanged.
B<device-write-iops-sec> is a single string listing one or more device/write_iops_sec
pairs, int the format of /path/to/device,write_iops_sec,/path/to/device,write_iops_sec.
Each write_iops_sec is a number which type is unsigned int, value 0 to remove that
device from per-decice listing.
Only the devices listed in the string are modified;
any existing per-device write_iops_sec for other devices remain unchanged.
B<device-read-bytes-sec> is a single string listing one or more device/read_bytes_sec
pairs, int the format of /path/to/device,read_bytes_sec,/path/to/device,read_bytes_sec.
Each read_bytes_sec is a number which type is unsigned long long, value 0 to remove
that device from per-decice listing.
Only the devices listed in the string are modified;
any existing per-device read_bytes_sec for other devices remain unchanged.
B<device-write-bytes-sec> is a single string listing one or more device/write_bytes_sec
pairs, int the format of /path/to/device,write_bytes_sec,/path/to/device,write_bytes_sec.
Each write_bytes_sec is a number which type is unsigned long long, value 0 to remove
that device from per-decice listing.
Only the devices listed in the string are modified;
any existing per-device write_bytes_sec for other devices remain unchanged.
If I<--live> is specified, affect a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on hypervisor.
=item B<setvcpus> I<domain> I<count> [I<--maximum>] [[I<--config>]
[I<--live>] | [I<--current>]] [I<--guest>]
Change the number of virtual CPUs active in a guest domain. By default,
this command works on active guest domains. To change the settings for an
inactive guest domain, use the I<--config> flag.
The I<count> value may be limited by host, hypervisor, or a limit coming
from the original description of the guest domain. For Xen, you can only
adjust the virtual CPUs of a running domain if the domain is paravirtualized.
If the I<--config> flag is specified, the change is made to the stored XML
configuration for the guest domain, and will only take effect when the guest
domain is next started.
If I<--live> is specified, the guest domain must be active, and the change
takes place immediately. Both the I<--config> and I<--live> flags may be
specified together if supported by the hypervisor. If this command is run
before the guest has finished booting, the guest may fail to process
the change.
If I<--current> is specified, affect the current guest state.
When no flags are given, the I<--live>
flag is assumed and the guest domain must be active. In this situation it
is up to the hypervisor whether the I<--config> flag is also assumed, and
therefore whether the XML configuration is adjusted to make the change
persistent.
If I<--guest> is specified, then the count of cpus is modified in the guest
instead of the hypervisor. This flag is usable only for live domains
and may require guest agent to be configured in the guest.
The I<--maximum> flag controls the maximum number of virtual cpus that can
be hot-plugged the next time the domain is booted. As such, it must only be
used with the I<--config> flag, and not with the I<--live> flag.
=item B<shutdown> I<domain> [I<--mode MODE-LIST>]
Gracefully shuts down a domain. This coordinates with the domain OS
to perform graceful shutdown, so there is no guarantee that it will
succeed, and may take a variable length of time depending on what
services must be shutdown in the domain.
The exact behavior of a domain when it shuts down is set by the
I<on_shutdown> parameter in the domain's XML definition.
If I<domain> is transient, then the metadata of any snapshots will
be lost once the guest stops running, but the snapshot contents still
exist, and a new domain with the same name and UUID can restore the
snapshot metadata with B<snapshot-create>.
By default the hypervisor will try to pick a suitable shutdown
method. To specify an alternative method, the I<--mode> parameter
can specify a comma separated list which includes C<acpi>, C<agent>,
C<initctl>, C<signal> and C<paravirt>. The order in which drivers will
try each mode is undefined, and not related to the order specified to virsh.
For strict control over ordering, use a single mode at a time and
repeat the command.
=item B<start> I<domain-name-or-uuid> [I<--console>] [I<--paused>]
[I<--autodestroy>] [I<--bypass-cache>] [I<--force-boot>] [I<--pass-fds N,M,...>]
Start a (previously defined) inactive domain, either from the last
B<managedsave> state, or via a fresh boot if no managedsave state is
present. The domain will be paused if the I<--paused> option is
used and supported by the driver; otherwise it will be running.
If I<--console> is requested, attach to the console after creation.
If I<--autodestroy> is requested, then the guest will be automatically
destroyed when virsh closes its connection to libvirt, or otherwise
exits. If I<--bypass-cache> is specified, and managedsave state exists,
the restore will avoid the file system cache, although this may slow
down the operation. If I<--force-boot> is specified, then any
managedsave state is discarded and a fresh boot occurs.
If I<--pass-fds> is specified, the argument is a comma separated list
of open file descriptors which should be pass on into the guest. The
file descriptors will be re-numered in the guest, starting from 3. This
is only supported with container based virtualization.
=item B<suspend> I<domain>
Suspend a running domain. It is kept in memory but won't be scheduled
anymore.
=item B<resume> I<domain>
Moves a domain out of the suspended state. This will allow a previously
suspended domain to now be eligible for scheduling by the underlying
hypervisor.
=item B<dompmsuspend> I<domain> I<target> [I<--duration>]
Suspend a running domain into one of these states (possible I<target>
values):
mem equivalent of S3 ACPI state
disk equivalent of S4 ACPI state
hybrid RAM is saved to disk but not powered off
The I<--duration> argument specifies number of seconds before the domain is
woken up after it was suspended (see also B<dompmwakeup>). Default is 0 for
unlimited suspend time. (This feature isn't currently supported by any
hypervisor driver and 0 should be used.).
Note that this command requires a guest agent configured and running in the
domain's guest OS.
Beware that at least for QEMU, the domain's process will be terminated when
target disk is used and a new process will be launched when libvirt is asked
to wake up the domain. As a result of this, any runtime changes, such as
device hotplug or memory settings, are lost unless such changes were made
with I<--config> flag.
=item B<dompmwakeup> I<domain>
Wakeup a domain from pmsuspended state (either suspended by dompmsuspend or
from the guest itself). Injects a wakeup into the guest that is in pmsuspended
state, rather than waiting for the previously requested duration (if any) to
elapse. This operation doesn't not necessarily fail if the domain is running.
=item B<ttyconsole> I<domain>
Output the device used for the TTY console of the domain. If the information
is not available the processes will provide an exit code of 1.
=item B<undefine> I<domain> [I<--managed-save>] [I<--snapshots-metadata>]
[I<--nvram>] [ {I<--storage> B<volumes> | I<--remove-all-storage>} I<--wipe-storage>]
Undefine a domain. If the domain is running, this converts it to a
transient domain, without stopping it. If the domain is inactive,
the domain configuration is removed.
The I<--managed-save> flag guarantees that any managed save image (see
the B<managedsave> command) is also cleaned up. Without the flag, attempts
to undefine a domain with a managed save image will fail.
The I<--snapshots-metadata> flag guarantees that any snapshots (see the
B<snapshot-list> command) are also cleaned up when undefining an inactive
domain. Without the flag, attempts to undefine an inactive domain with
snapshot metadata will fail. If the domain is active, this flag is
ignored.
The I<--nvram> flag ensures no nvram (/domain/os/nvram/) file is
left behind. If the domain has an nvram file and the flag is
omitted, the undefine will fail.
The I<--storage> flag takes a parameter B<volumes>, which is a comma separated
list of volume target names or source paths of storage volumes to be removed
along with the undefined domain. Volumes can be undefined and thus removed only
on inactive domains. Volume deletion is only attempted after the domain is
undefined; if not all of the requested volumes could be deleted, the
error message indicates what still remains behind. If a volume path is not
found in the domain definition, it's treated as if the volume was successfully
deleted. Only volumes managed by libvirt in storage pools can be removed this
way.
(See B<domblklist> for list of target names associated to a domain).
Example: --storage vda,/path/to/storage.img
The I<--remove-all-storage> flag specifies that all of the domain's storage
volumes should be deleted.
The flag I<--wipe-storage> specifies that the storage volumes should be
wiped before removal.
NOTE: For an inactive domain, the domain name or UUID must be used as the
I<domain>.
=item B<vcpucount> I<domain> [{I<--maximum> | I<--active>}
{I<--config> | I<--live> | I<--current>}] [I<--guest>]
Print information about the virtual cpu counts of the given
I<domain>. If no flags are specified, all possible counts are
listed in a table; otherwise, the output is limited to just the
numeric value requested. For historical reasons, the table
lists the label "current" on the rows that can be queried in isolation
via the I<--active> flag, rather than relating to the I<--current> flag.
I<--maximum> requests information on the maximum cap of vcpus that a
domain can add via B<setvcpus>, while I<--active> shows the current
usage; these two flags cannot both be specified. I<--config>
requires a persistent domain and requests information regarding the next
time the domain will be booted, I<--live> requires a running domain and
lists current values, and I<--current> queries according to the current
state of the domain (corresponding to I<--live> if running, or
I<--config> if inactive); these three flags are mutually exclusive.
If I<--guest> is specified, then the count of cpus is reported from
the perspective of the guest. This flag is usable only for live domains
and may require guest agent to be configured in the guest.
=item B<vcpuinfo> I<domain> [I<--pretty>]
Returns basic information about the domain virtual CPUs, like the number of
vCPUs, the running time, the affinity to physical processors.
With I<--pretty>, cpu affinities are shown as ranges.
=item B<vcpupin> I<domain> [I<vcpu>] [I<cpulist>] [[I<--live>]
[I<--config>] | [I<--current>]]
Query or change the pinning of domain VCPUs to host physical CPUs. To
pin a single I<vcpu>, specify I<cpulist>; otherwise, you can query one
I<vcpu> or omit I<vcpu> to list all at once.
I<cpulist> is a list of physical CPU numbers. Its syntax is a comma
separated list and a special markup using '-' and '^' (ex. '0-4', '0-3,^2') can
also be allowed. The '-' denotes the range and the '^' denotes exclusive.
If you want to reset vcpupin setting, that is, to pin vcpu all physical cpus,
simply specify 'r' as a cpulist.
If I<--live> is specified, affect a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--config> flags may be given if I<cpulist> is present,
but I<--current> is exclusive.
If no flag is specified, behavior is different depending on hypervisor.
B<Note>: The expression is sequentially evaluated, so "0-15,^8" is
identical to "9-14,0-7,15" but not identical to "^8,0-15".
=item B<emulatorpin> I<domain> [I<cpulist>] [[I<--live>] [I<--config>]
| [I<--current>]]
Query or change the pinning of domain's emulator threads to host physical
CPUs.
See B<vcpupin> for I<cpulist>.
If I<--live> is specified, affect a running guest.
If I<--config> is specified, affect the next boot of a persistent guest.
If I<--current> is specified, affect the current guest state.
Both I<--live> and I<--config> flags may be given if I<cpulist> is present,
but I<--current> is exclusive.
If no flag is specified, behavior is different depending on hypervisor.
=item B<vncdisplay> I<domain>
Output the IP address and port number for the VNC display. If the information
is not available the processes will provide an exit code of 1.
=back
=head1 DEVICE COMMANDS
The following commands manipulate devices associated to domains.
The I<domain> can be specified as a short integer, a name or a full UUID.
To better understand the values allowed as options for the command
reading the documentation at L<http://libvirt.org/formatdomain.html> on the
format of the device sections to get the most accurate set of accepted values.
=over 4
=item B<attach-device> I<domain> I<FILE>
[[[I<--live>] [I<--config>] | [I<--current>]] | [I<--persistent>]]
Attach a device to the domain, using a device definition in an XML
file using a device definition element such as <disk> or <interface>
as the top-level element. See the documentation at
L<http://libvirt.org/formatdomain.html#elementsDevices> to learn about
libvirt XML format for a device. If I<--config> is specified the
command alters the persistent domain configuration with the device
attach taking effect the next time libvirt starts the domain.
For cdrom and floppy devices, this command only replaces the media
within an existing device; consider using B<update-device> for this
usage. For passthrough host devices, see also B<nodedev-detach>,
needed if the PCI device does not use managed mode.
If I<--live> is specified, affect a running domain.
If I<--config> is specified, affect the next startup of a persistent domain.
If I<--current> is specified, affect the current domain state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. When no flag is specified legacy API is used whose behavior depends
on the hypervisor driver.
For compatibility purposes, I<--persistent> behaves like I<--config> for
an offline domain, and like I<--live> I<--config> for a running domain.
B<Note>: using of partial device definition XML files may lead to unexpected
results as some fields may be autogenerated and thus match devices other than
expected.
=item B<attach-disk> I<domain> I<source> I<target> [[[I<--live>] [I<--config>]
| [I<--current>]] | [I<--persistent>]] [I<--targetbus bus>] [I<--driver
driver>] [I<--subdriver subdriver>] [I<--iothread iothread>]
[I<--cache cache>] [I<--type type>]
[I<--mode mode>] [I<--sourcetype sourcetype>] [I<--serial serial>] [I<--wwn
wwn>] [I<--rawio>] [I<--address address>] [I<--multifunction>] [I<--print-xml>]
Attach a new disk device to the domain.
I<source> is path for the files and devices. I<target> controls the bus or
device under which the disk is exposed to the guest OS. It indicates the
"logical" device name; the optional I<targetbus> attribute specifies the type
of disk device to emulate; possible values are driver specific, with typical
values being I<ide>, I<scsi>, I<virtio>, I<xen>, I<usb>, I<sata>, or I<sd>, if
omitted, the bus type is inferred from the style of the device name (e.g. a
device named 'sda' will typically be exported using a SCSI bus). I<driver> can
be I<file>, I<tap> or I<phy> for the Xen
hypervisor depending on the kind of access; or I<qemu> for the QEMU emulator.
Further details to the driver can be passed using I<subdriver>. For Xen
I<subdriver> can be I<aio>, while for QEMU subdriver should match the format
of the disk source, such as I<raw> or I<qcow2>. Hypervisor default will be
used if I<subdriver> is not specified. However, the default may not be
correct, esp. for QEMU as for security reasons it is configured not to detect
disk formats. I<type> can indicate I<lun>, I<cdrom> or I<floppy> as
alternative to the disk default, although this use only replaces the media
within the existing virtual cdrom or floppy device; consider using
B<update-device> for this usage instead.
I<mode> can specify the two specific mode I<readonly> or I<shareable>.
I<sourcetype> can indicate the type of source (block|file)
I<cache> can be one of "default", "none", "writethrough", "writeback",
"directsync" or "unsafe".
I<iothread> is the number within the range of domain IOThreads to which
this disk may be attached (QEMU only).
I<serial> is the serial of disk device. I<wwn> is the wwn of disk device.
I<rawio> indicates the disk needs rawio capability.
I<address> is the address of disk device in the form of pci:domain.bus.slot.function,
scsi:controller.bus.unit or ide:controller.bus.unit.
I<multifunction> indicates specified pci address is a multifunction pci device
address.
If I<--print-xml> is specified, then the XML of the disk that would be attached
is printed instead.
If I<--live> is specified, affect a running domain.
If I<--config> is specified, affect the next startup of a persistent domain.
If I<--current> is specified, affect the current domain state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. When no flag is specified legacy API is used whose behavior depends
on the hypervisor driver.
For compatibility purposes, I<--persistent> behaves like I<--config> for
an offline domain, and like I<--live> I<--config> for a running domain.
Likewise, I<--shareable> is an alias for I<--mode shareable>.
=item B<attach-interface> I<domain> I<type> I<source>
[[[I<--live>] [I<--config>] | [I<--current>]] | [I<--persistent>]]
[I<--target target>] [I<--mac mac>] [I<--script script>] [I<--model model>]
[I<--config>] [I<--inbound average,peak,burst>] [I<--outbound average,peak,burst>]
Attach a new network interface to the domain. I<type> can be either
I<network> to indicate connection via a libvirt virtual network or
I<bridge> to indicate connection via a bridge device on the host.
I<source> indicates the source of the connection (either the name of a
network, or of a bridge device). I<target> is used to specify the
tap/macvtap device to be used to connect the domain to the
source. Names starting with 'vnet' are considered as auto-generated
and are blanked out/regenerated each time the interface is attached.
I<mac> specifies the MAC address of the network interface; if a MAC
address is not given, a new address will be automatically generated
(and stored in the persistent configuration if "--config" is given on
the commandline). I<script> is used to specify a path to a custom
script to be called while attaching to a bridge - this will be called
instead of the default script not in addition to it; --script is valid
only for interfaces of type I<bridge> and only for Xen domains.
I<model> specifies the network device model to be presented to the
domain. I<inbound> and I<outbound> control the bandwidth of the
interface. I<peak> and I<burst> are optional, so "average,peak",
"average,,burst" and "average" are also legal. Values for I<average>
and I<peak> are expressed in kilobytes per second, while I<burst> is
expressed in kilobytes in a single burst at -I<peak> speed as
described in the Network XML documentation at
L<http://libvirt.org/formatnetwork.html#elementQoS>.
If I<--live> is specified, affect a running domain.
If I<--config> is specified, affect the next startup of a persistent domain.
If I<--current> is specified, affect the current domain state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. When no flag is specified legacy API is used whose behavior depends
on the hypervisor driver.
For compatibility purposes, I<--persistent> behaves like I<--config> for
an offline domain, and like I<--live> I<--config> for a running domain.
B<Note>: the optional target value is the name of a device to be created
as the back-end on the node. If not provided a device named "vnetN" or "vifN"
will be created automatically.
=item B<detach-device> I<domain> I<FILE>
[[[I<--live>] [I<--config>] | [I<--current>]] | [I<--persistent>]]
Detach a device from the domain, takes the same kind of XML descriptions
as command B<attach-device>.
For passthrough host devices, see also B<nodedev-reattach>, needed if
the device does not use managed mode.
B<Note>: using of partial device definition XML files may lead to unexpected
results as some fields may be autogenerated and thus match devices other than
expected.
If I<--live> is specified, affect a running domain.
If I<--config> is specified, affect the next startup of a persistent domain.
If I<--current> is specified, affect the current domain state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. When no flag is specified legacy API is used whose behavior depends
on the hypervisor driver.
For compatibility purposes, I<--persistent> behaves like I<--config> for
an offline domain, and like I<--live> I<--config> for a running domain.
Note that older versions of virsh used I<--config> as an alias for
I<--persistent>.
=item B<detach-disk> I<domain> I<target>
[[[I<--live>] [I<--config>] | [I<--current>]] | [I<--persistent>]]
Detach a disk device from a domain. The I<target> is the device as seen
from the domain.
If I<--live> is specified, affect a running domain.
If I<--config> is specified, affect the next startup of a persistent domain.
If I<--current> is specified, affect the current domain state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. When no flag is specified legacy API is used whose behavior depends
on the hypervisor driver.
For compatibility purposes, I<--persistent> behaves like I<--config> for
an offline domain, and like I<--live> I<--config> for a running domain.
Note that older versions of virsh used I<--config> as an alias for
I<--persistent>.
=item B<detach-interface> I<domain> I<type> [I<--mac mac>]
[[[I<--live>] [I<--config>] | [I<--current>]] | [I<--persistent>]]
Detach a network interface from a domain.
I<type> can be either I<network> to indicate a physical network device or
I<bridge> to indicate a bridge to a device. It is recommended to use the
I<mac> option to distinguish between the interfaces if more than one are
present on the domain.
If I<--live> is specified, affect a running domain.
If I<--config> is specified, affect the next startup of a persistent domain.
If I<--current> is specified, affect the current domain state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. When no flag is specified legacy API is used whose behavior depends
on the hypervisor driver.
For compatibility purposes, I<--persistent> behaves like I<--config> for
an offline domain, and like I<--live> I<--config> for a running domain.
Note that older versions of virsh used I<--config> as an alias for
I<--persistent>.
=item B<update-device> I<domain> I<file> [I<--force>]
[[[I<--live>] [I<--config>] | [I<--current>]] | [I<--persistent>]]
Update the characteristics of a device associated with I<domain>,
based on the device definition in an XML I<file>. The I<--force> option
can be used to force device update, e.g., to eject a CD-ROM even if it is
locked/mounted in the domain. See the documentation at
L<http://libvirt.org/formatdomain.html#elementsDevices> to learn about
libvirt XML format for a device.
If I<--live> is specified, affect a running domain.
If I<--config> is specified, affect the next startup of a persistent domain.
If I<--current> is specified, affect the current domain state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. Not specifying any flag is the same as specifying I<--current>.
For compatibility purposes, I<--persistent> behaves like I<--config> for
an offline domain, and like I<--live> I<--config> for a running domain.
Note that older versions of virsh used I<--config> as an alias for
I<--persistent>.
B<Note>: using of partial device definition XML files may lead to unexpected
results as some fields may be autogenerated and thus match devices other than
expected.
=item B<change-media> I<domain> I<path> [I<--eject>] [I<--insert>]
[I<--update>] [I<source>] [I<--force>] [[I<--live>] [I<--config>] | [I<--current>]]
Change media of CDROM or floppy drive. I<path> can be the fully-qualified path
or the unique target name (<target dev='hdc'>) of the disk device. I<source>
specifies the path of the media to be inserted or updated.
I<--eject> indicates the media will be ejected.
I<--insert> indicates the media will be inserted. I<source> must be specified.
If the device has source (e.g. <source file='media'>), and I<source> is not
specified, I<--update> is equal to I<--eject>. If the device has no source,
and I<source> is specified, I<--update> is equal to I<--insert>. If the device
has source, and I<source> is specified, I<--update> behaves like combination
of I<--eject> and I<--insert>.
If none of I<--eject>, I<--insert>, and I<--update> is specified, I<--update>
is used by default.
The I<--force> option can be used to force media changing.
If I<--live> is specified, alter live configuration of running guest.
If I<--config> is specified, alter persistent configuration, effect observed
on next boot.
I<--current> can be either or both of I<live> and I<config>, depends on
the hypervisor's implementation.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. If no flag is specified, behavior is different depending
on hypervisor.
=back
=head1 NODEDEV COMMANDS
The following commands manipulate host devices that are intended to be
passed through to guest domains via <hostdev> elements in a domain's
<devices> section. A node device key is generally specified by the bus
name followed by its address, using underscores between all components,
such as pci_0000_00_02_1, usb_1_5_3, or net_eth1_00_27_13_6a_fe_00.
The B<nodedev-list> gives the full list of host devices that are known
to libvirt, although this includes devices that cannot be assigned to
a guest (for example, attempting to detach the PCI device that controls
the host's hard disk controller where the guest's disk images live could
cause the host system to lock up or reboot).
For more information on node device definition see:
L<http://libvirt.org/formatnode.html>.
Passthrough devices cannot be simultaneously used by the host and its
guest domains, nor by multiple active guests at once. If the
<hostdev> description of a PCI device includes the attribute B<managed='yes'>,
and the hypervisor driver supports it, then the device is in managed mode, and
attempts to use that passthrough device in an active guest will
automatically behave as if B<nodedev-detach> (guest start, device
hot-plug) and B<nodedev-reattach> (guest stop, device hot-unplug) were
called at the right points. If a PCI device is not marked as managed,
then it must manually be detached before guests can use it, and manually
reattached to be returned to the host. Also, if a device is manually detached,
then the host does not regain control of the device without a matching
reattach, even if the guests use the device in managed mode.
=over 4
=item B<nodedev-create> I<FILE>
Create a device on the host node that can then be assigned to virtual
machines. Normally, libvirt is able to automatically determine which
host nodes are available for use, but this allows registration of
host hardware that libvirt did not automatically detect. I<file>
contains xml for a top-level <device> description of a node device.
=item B<nodedev-destroy> I<device>
Destroy (stop) a device on the host. I<device> can be either device
name or wwn pair in "wwnn,wwpn" format (only works for vHBA currently).
Note that this makes libvirt quit managing a host device, and may even
make that device unusable by the rest of the physical host until a reboot.
=item B<nodedev-detach> I<nodedev> [I<--driver backend_driver>]
Detach I<nodedev> from the host, so that it can safely be used by
guests via <hostdev> passthrough. This is reversed with
B<nodedev-reattach>, and is done automatically for managed devices.
For compatibility purposes, this command can also be spelled
B<nodedev-dettach>.
Different backend drivers expect the device to be bound to different
dummy devices. For example, QEMU's "kvm" backend driver (the default)
expects the device to be bound to pci-stub, but its "vfio" backend
driver expects the device to be bound to vfio-pci. The I<--driver>
parameter can be used to specify the desired backend driver.
=item B<nodedev-dumpxml> I<device>
Dump a <device> XML representation for the given node device, including
such information as the device name, which bus owns the device, the
vendor and product id, and any capabilities of the device usable by
libvirt (such as whether device reset is supported). I<device> can
be either device name or wwn pair in "wwnn,wwpn" format (only works
for HBA).
=item B<nodedev-list> I<cap> I<--tree>
List all of the devices available on the node that are known by libvirt.
I<cap> is used to filter the list by capability types, the types must be
separated by comma, e.g. --cap pci,scsi, valid capability types include
'system', 'pci', 'usb_device', 'usb', 'net', 'scsi_host', 'scsi_target',
'scsi', 'storage', 'fc_host', 'vports', 'scsi_generic'. If I<--tree> is
used, the output is formatted in a tree representing parents of each node.
I<cap> and I<--tree> are mutually exclusive.
=item B<nodedev-reattach> I<nodedev>
Declare that I<nodedev> is no longer in use by any guests, and that
the host can resume normal use of the device. This is done
automatically for PCI devices in managed mode and USB devices, but
must be done explicitly to match any explicit B<nodedev-detach>.
=item B<nodedev-reset> I<nodedev>
Trigger a device reset for I<nodedev>, useful prior to transferring
a node device between guest passthrough or the host. Libvirt will
often do this action implicitly when required, but this command
allows an explicit reset when needed.
=back
=head1 VIRTUAL NETWORK COMMANDS
The following commands manipulate networks. Libvirt has the capability to
define virtual networks which can then be used by domains and linked to
actual network devices. For more detailed information about this feature
see the documentation at L<http://libvirt.org/formatnetwork.html> . Many
of the commands for virtual networks are similar to the ones used for domains,
but the way to name a virtual network is either by its name or UUID.
=over 4
=item B<net-autostart> I<network> [I<--disable>]
Configure a virtual network to be automatically started at boot.
The I<--disable> option disable autostarting.
=item B<net-create> I<file>
Create a transient (temporary) virtual network from an
XML I<file> and instantiate (start) the network.
See the documentation at L<http://libvirt.org/formatnetwork.html>
to get a description of the XML network format used by libvirt.
=item B<net-define> I<file>
Define a persistent virtual network from an XML I<file>, the network is just
defined but not instantiated (started).
=item B<net-destroy> I<network>
Destroy (stop) a given transient or persistent virtual network
specified by its name or UUID. This takes effect immediately.
=item B<net-dumpxml> I<network> [I<--inactive>]
Output the virtual network information as an XML dump to stdout.
If I<--inactive> is specified, then physical functions are not
expanded into their associated virtual functions.
=item B<net-edit> I<network>
Edit the XML configuration file for a network.
This is equivalent to:
virsh net-dumpxml --inactive network > network.xml
vi network.xml (or make changes with your other text editor)
virsh net-define network.xml
except that it does some error checking.
The editor used can be supplied by the C<$VISUAL> or C<$EDITOR> environment
variables, and defaults to C<vi>.
=item B<net-event> {[I<network>] I<event> [I<--loop>] [I<--timeout>
I<seconds>] | I<--list>}
Wait for a class of network events to occur, and print appropriate details
of events as they happen. The events can optionally be filtered by
I<network>. Using I<--list> as the only argument will provide a list
of possible I<event> values known by this client, although the connection
might not allow registering for all these events.
By default, this command is one-shot, and returns success once an event
occurs; you can send SIGINT (usually via C<Ctrl-C>) to quit immediately.
If I<--timeout> is specified, the command gives up waiting for events
after I<seconds> have elapsed. With I<--loop>, the command prints all
events until a timeout or interrupt key.
=item B<net-info> I<network>
Returns basic information about the I<network> object.
=item B<net-list> [I<--inactive> | I<--all>]
[I<--persistent>] [<--transient>]
[I<--autostart>] [<--no-autostart>]
Returns the list of active networks, if I<--all> is specified this will also
include defined but inactive networks, if I<--inactive> is specified only the
inactive ones will be listed. You may also want to filter the returned networks
by I<--persistent> to list the persistent ones, I<--transient> to list the
transient ones, I<--autostart> to list the ones with autostart enabled, and
I<--no-autostart> to list the ones with autostart disabled.
NOTE: When talking to older servers, this command is forced to use a series of
API calls with an inherent race, where a pool might not be listed or might appear
more than once if it changed state between calls while the list was being
collected. Newer servers do not have this problem.
=item B<net-name> I<network-UUID>
Convert a network UUID to network name.
=item B<net-start> I<network>
Start a (previously defined) inactive network.
=item B<net-undefine> I<network>
Undefine the configuration for a persistent network. If the network is active,
make it transient.
=item B<net-uuid> I<network-name>
Convert a network name to network UUID.
=item B<net-update> I<network> I<command> I<section> I<xml>
[I<--parent-index> I<index>] [[I<--live>] [I<--config>] | [I<--current>]]
Update the given section of an existing network definition, with the
changes optionally taking effect immediately, without needing to
destroy and re-start the network.
I<command> is one of "add-first", "add-last", "add" (a synonym for
add-last), "delete", or "modify".
I<section> is one of "bridge", "domain", "ip", "ip-dhcp-host",
"ip-dhcp-range", "forward", "forward-interface", "forward-pf",
"portgroup", "dns-host", "dns-txt", or "dns-srv", each section being
named by a concatenation of the xml element hierarchy leading to the
element being changed. For example, "ip-dhcp-host" will change a
<host> element that is contained inside a <dhcp> element inside an
<ip> element of the network.
I<xml> is either the text of a complete xml element of the type being
changed (e.g. "<host mac="00:11:22:33:44:55' ip='1.2.3.4'/>", or the
name of a file that contains a complete xml element. Disambiguation is
done by looking at the first character of the provided text - if the
first character is "<", it is xml text, if the first character is not
"<", it is the name of a file that contains the xml text to be used.
The I<--parent-index> option is used to specify which of several
parent elements the requested element is in (0-based). For example, a
dhcp <host> element could be in any one of multiple <ip> elements in
the network; if a parent-index isn't provided, the "most appropriate"
<ip> element will be selected (usually the only one that already has a
<dhcp> element), but if I<--parent-index> is given, that particular
instance of <ip> will get the modification.
If I<--live> is specified, affect a running network.
If I<--config> is specified, affect the next startup of a persistent network.
If I<--current> is specified, affect the current network state.
Both I<--live> and I<--config> flags may be given, but I<--current> is
exclusive. Not specifying any flag is the same as specifying I<--current>.
=item B<net-dhcp-leases> I<network> [I<mac>]
Get a list of dhcp leases for all network interfaces connected to the given
virtual I<network> or limited output just for one interface if I<mac> is
specified.
=back
=head1 INTERFACE COMMANDS
The following commands manipulate host interfaces. Often, these host
interfaces can then be used by name within domain <interface> elements
(such as a system-created bridge interface), but there is no
requirement that host interfaces be tied to any particular guest
configuration XML at all.
Many of the commands for host interfaces are similar to the ones used
for domains, and the way to name an interface is either by its name or
its MAC address. However, using a MAC address for an I<iface>
argument only works when that address is unique (if an interface and a
bridge share the same MAC address, which is often the case, then using
that MAC address results in an error due to ambiguity, and you must
resort to a name instead).
=over 4
=item B<iface-bridge> I<interface> I<bridge> [I<--no-stp>] [I<delay>]
[I<--no-start>]
Create a bridge device named I<bridge>, and attach the existing
network device I<interface> to the new bridge. The new bridge
defaults to starting immediately, with STP enabled and a delay of 0;
these settings can be altered with I<--no-stp>, I<--no-start>, and an
integer number of seconds for I<delay>. All IP address configuration
of I<interface> will be moved to the new bridge device.
See also B<iface-unbridge> for undoing this operation.
=item B<iface-define> I<file>
Define a host interface from an XML I<file>, the interface is just defined but
not started.
=item B<iface-destroy> I<interface>
Destroy (stop) a given host interface, such as by running "if-down" to
disable that interface from active use. This takes effect immediately.
=item B<iface-dumpxml> I<interface> [I<--inactive>]
Output the host interface information as an XML dump to stdout. If
I<--inactive> is specified, then the output reflects the persistent
state of the interface that will be used the next time it is started.
=item B<iface-edit> I<interface>
Edit the XML configuration file for a host interface.
This is equivalent to:
virsh iface-dumpxml iface > iface.xml
vi iface.xml (or make changes with your other text editor)
virsh iface-define iface.xml
except that it does some error checking.
The editor used can be supplied by the C<$VISUAL> or C<$EDITOR> environment
variables, and defaults to C<vi>.
=item B<iface-list> [I<--inactive> | I<--all>]
Returns the list of active host interfaces. If I<--all> is specified
this will also include defined but inactive interfaces. If
I<--inactive> is specified only the inactive ones will be listed.
=item B<iface-name> I<interface>
Convert a host interface MAC to interface name, if the MAC address is unique
among the host's interfaces.
I<interface> specifies the interface MAC address.
=item B<iface-mac> I<interface>
Convert a host interface name to MAC address.
I<interface> specifies the interface name.
=item B<iface-start> I<interface>
Start a (previously defined) host interface, such as by running "if-up".
=item B<iface-unbridge> I<bridge> [I<--no-start>]
Tear down a bridge device named I<bridge>, releasing its underlying
interface back to normal usage, and moving all IP address
configuration from the bridge device to the underlying device. The
underlying interface is restarted unless I<--no-start> is present;
this flag is present for symmetry, but generally not recommended.
See also B<iface-bridge> for creating a bridge.
=item B<iface-undefine> I<interface>
Undefine the configuration for an inactive host interface.
=item B<iface-begin>
Create a snapshot of current host interface settings, which can later
be committed (I<iface-commit>) or restored (I<iface-rollback>). If a
snapshot already exists, then this command will fail until the
previous snapshot has been committed or restored. Undefined behavior
results if any external changes are made to host interfaces outside of
the libvirt API between the beginning of a snapshot and its eventual
commit or rollback.
=item B<iface-commit>
Declare all changes since the last I<iface-begin> as working, and
delete the rollback point. If no interface snapshot has already been
started, then this command will fail.
=item B<iface-rollback>
Revert all host interface settings back to the state recorded in the
last I<iface-begin>. If no interface snapshot has already been
started, then this command will fail. Rebooting the host also serves
as an implicit rollback point.
=back
=head1 STORAGE POOL COMMANDS
The following commands manipulate storage pools. Libvirt has the
capability to manage various storage solutions, including files, raw
partitions, and domain-specific formats, used to provide the storage
volumes visible as devices within virtual machines. For more detailed
information about this feature, see the documentation at
L<http://libvirt.org/formatstorage.html> . Many of the commands for
pools are similar to the ones used for domains.
=over 4
=item B<find-storage-pool-sources> I<type> [I<srcSpec>]
Returns XML describing all storage pools of a given I<type> that could
be found. If I<srcSpec> is provided, it is a file that contains XML
to further restrict the query for pools.
=item B<find-storage-pool-sources-as> I<type> [I<host>] [I<port>]
[I<initiator>]
Returns XML describing all storage pools of a given I<type> that could
be found. If I<host>, I<port>, or I<initiator> are provided, they control
where the query is performed.
=item B<pool-autostart> I<pool-or-uuid> [I<--disable>]
Configure whether I<pool> should automatically start at boot.
=item B<pool-build> I<pool-or-uuid> [I<--overwrite>] [I<--no-overwrite>]
Build a given pool.
Options I<--overwrite> and I<--no-overwrite> can only be used for
B<pool-build> a filesystem pool. If neither of them is specified,
B<pool-build> on a filesystem pool only makes the directory; If
I<--no-overwrite> is specified, it probes to determine if a
filesystem already exists on the target device, returning an error
if exists, or using mkfs to format the target device if not; If
I<--overwrite> is specified, mkfs is always executed, any existed
data on the target device is overwritten unconditionally.
=item B<pool-create> I<file>
Create and start a pool object from the XML I<file>.
=item B<pool-create-as> I<name> I<--print-xml> I<type> [I<source-host>]
[I<source-path>] [I<source-dev>] [I<source-name>] [<target>]
[I<--source-format format>]
Create and start a pool object I<name> from the raw parameters. If
I<--print-xml> is specified, then print the XML of the pool object
without creating the pool. Otherwise, the pool has the specified
I<type>.
=item B<pool-define> I<file>
Create, but do not start, a pool object from the XML I<file>.
=item B<pool-define-as> I<name> I<--print-xml> I<type> [I<source-host>]
[I<source-path>] [I<source-dev>] [I<source-name>] [<target>]
[I<--source-format format>]
Create, but do not start, a pool object I<name> from the raw parameters. If
I<--print-xml> is specified, then print the XML of the pool object
without defining the pool. Otherwise, the pool has the specified
I<type>.
=item B<pool-destroy> I<pool-or-uuid>
Destroy (stop) a given I<pool> object. Libvirt will no longer manage the
storage described by the pool object, but the raw data contained in
the pool is not changed, and can be later recovered with
B<pool-create>.
=item B<pool-delete> I<pool-or-uuid>
Destroy the resources used by a given I<pool> object. This operation
is non-recoverable. The I<pool> object will still exist after this
command, ready for the creation of new storage volumes.
=item B<pool-dumpxml> [I<--inactive>] I<pool-or-uuid>
Returns the XML information about the I<pool> object.
I<--inactive> tells virsh to dump pool configuration that will be used
on next start of the pool as opposed to the current pool configuration.
=item B<pool-edit> I<pool-or-uuid>
Edit the XML configuration file for a storage pool.
This is equivalent to:
virsh pool-dumpxml pool > pool.xml
vi pool.xml (or make changes with your other text editor)
virsh pool-define pool.xml
except that it does some error checking.
The editor used can be supplied by the C<$VISUAL> or C<$EDITOR> environment
variables, and defaults to C<vi>.
=item B<pool-info> I<pool-or-uuid>
Returns basic information about the I<pool> object.
=item B<pool-list> [I<--inactive>] [I<--all>]
[I<--persistent>] [I<--transient>]
[I<--autostart>] [I<--no-autostart>]
[[I<--details>] [<type>]
List pool objects known to libvirt. By default, only active pools
are listed; I<--inactive> lists just the inactive pools, and I<--all>
lists all pools.
In addition, there are several sets of filtering flags. I<--persistent> is to
list the persistent pools, I<--transient> is to list the transient pools.
I<--autostart> lists the autostarting pools, I<--no-autostart> lists the pools
with autostarting disabled.
You may also want to list pools with specified types using I<type>, the
pool types must be separated by comma, e.g. --type dir,disk. The valid pool
types include 'dir', 'fs', 'netfs', 'logical', 'disk', 'iscsi', 'scsi',
'mpath', 'rbd', 'sheepdog' and 'gluster'.
The I<--details> option instructs virsh to additionally
display pool persistence and capacity related information where available.
NOTE: When talking to older servers, this command is forced to use a series of
API calls with an inherent race, where a pool might not be listed or might appear
more than once if it changed state between calls while the list was being
collected. Newer servers do not have this problem.
=item B<pool-name> I<uuid>
Convert the I<uuid> to a pool name.
=item B<pool-refresh> I<pool-or-uuid>
Refresh the list of volumes contained in I<pool>.
=item B<pool-start> I<pool-or-uuid>
Start the storage I<pool>, which is previously defined but inactive.
B<Note>: A storage pool that relies on remote resources such as an
"iscsi" or a (v)HBA backed "scsi" pool may need to be refreshed multiple
times in order to have all the volumes detected (see B<pool-refresh>).
This is because the corresponding volume devices may not be present in
the host's filesystem during the initial pool startup or the current
refresh attempt. The number of refresh retries is dependant upon the
network connection and the time the host takes to export the
corresponding devices.
=item B<pool-undefine> I<pool-or-uuid>
Undefine the configuration for an inactive I<pool>.
=item B<pool-uuid> I<pool>
Returns the UUID of the named I<pool>.
=back
=head1 VOLUME COMMANDS
=over 4
=item B<vol-create> I<pool-or-uuid> I<FILE> [I<--prealloc-metadata>]
Create a volume from an XML <file>.
I<pool-or-uuid> is the name or UUID of the storage pool to create the volume in.
I<FILE> is the XML <file> with the volume definition. An easy way to create the
XML <file> is to use the B<vol-dumpxml> command to obtain the definition of a
pre-existing volume.
[I<--prealloc-metadata>] preallocate metadata (for qcow2 images which don't
support full allocation). This option creates a sparse image file with metadata,
resulting in higher performance compared to images with no preallocation and
only slightly higher initial disk space usage.
B<Example>
virsh vol-dumpxml --pool storagepool1 appvolume1 > newvolume.xml
vi newvolume.xml (or make changes with your other text editor)
virsh vol-create differentstoragepool newvolume.xml
=item B<vol-create-from> I<pool-or-uuid> I<FILE> [I<--inputpool>
I<pool-or-uuid>] I<vol-name-or-key-or-path> [I<--prealloc-metadata>]
Create a volume, using another volume as input.
I<pool-or-uuid> is the name or UUID of the storage pool to create the volume in.
I<FILE> is the XML <file> with the volume definition.
I<--inputpool> I<pool-or-uuid> is the name or uuid of the storage pool the
source volume is in.
I<vol-name-or-key-or-path> is the name or key or path of the source volume.
[I<--prealloc-metadata>] preallocate metadata (for qcow2 images which don't
support full allocation). This option creates a sparse image file with metadata,
resulting in higher performance compared to images with no preallocation and
only slightly higher initial disk space usage.
=item B<vol-create-as> I<pool-or-uuid> I<name> I<capacity>
[I<--allocation> I<size>] [I<--format> I<string>] [I<--backing-vol>
I<vol-name-or-key-or-path>] [I<--backing-vol-format> I<string>]
[I<--prealloc-metadata>]
Create a volume from a set of arguments.
I<pool-or-uuid> is the name or UUID of the storage pool to create the volume
in.
I<name> is the name of the new volume.
I<capacity> is the size of the volume to be created, as a scaled integer
(see B<NOTES> above), defaulting to bytes if there is no suffix.
I<--allocation> I<size> is the initial size to be allocated in the volume,
also as a scaled integer defaulting to bytes.
I<--format> I<string> is used in file based storage pools to specify the volume
file format to use; raw, bochs, qcow, qcow2, vmdk, qed.
I<--backing-vol> I<vol-name-or-key-or-path> is the source backing
volume to be used if taking a snapshot of an existing volume.
I<--backing-vol-format> I<string> is the format of the snapshot backing volume;
raw, bochs, qcow, qcow2, qed, vmdk, host_device. These are, however, meant for
file based storage pools.
[I<--prealloc-metadata>] preallocate metadata (for qcow2 images which don't
support full allocation). This option creates a sparse image file with metadata,
resulting in higher performance compared to images with no preallocation and
only slightly higher initial disk space usage.
=item B<vol-clone> [I<--pool> I<pool-or-uuid>] I<vol-name-or-key-or-path>
I<name> [I<--prealloc-metadata>]
Clone an existing volume. Less powerful, but easier to type, version of
B<vol-create-from>.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool to create
the volume in.
I<vol-name-or-key-or-path> is the name or key or path of the source volume.
I<name> is the name of the new volume.
[I<--prealloc-metadata>] preallocate metadata (for qcow2 images which don't
support full allocation). This option creates a sparse image file with metadata,
resulting in higher performance compared to images with no preallocation and
only slightly higher initial disk space usage.
=item B<vol-delete> [I<--pool> I<pool-or-uuid>] I<vol-name-or-key-or-path>
Delete a given volume.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in.
I<vol-name-or-key-or-path> is the name or key or path of the volume to delete.
=item B<vol-upload> [I<--pool> I<pool-or-uuid>] [I<--offset> I<bytes>]
[I<--length> I<bytes>] I<vol-name-or-key-or-path> I<local-file>
Upload the contents of I<local-file> to a storage volume.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in.
I<vol-name-or-key-or-path> is the name or key or path of the volume where the
file will be uploaded.
I<--offset> is the position in the storage volume at which to start writing
the data. The value must be 0 or larger. I<--length> is an upper bound
of the amount of data to be uploaded. A negative value is interpreted
as an unsigned long long value to essentially include everything from
the offset to the end of the volume.
An error will occur if the I<local-file> is greater than the specified length.
See the description for the libvirt virStorageVolUpload API for details
regarding possible target volume and pool changes as a result of the
pool refresh when the upload is attempted.
=item B<vol-download> [I<--pool> I<pool-or-uuid>] [I<--offset> I<bytes>]
[I<--length> I<bytes>] I<vol-name-or-key-or-path> I<local-file>
Download the contents of a storage volume to I<local-file>.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in.
I<vol-name-or-key-or-path> is the name or key or path of the volume to download.
I<--offset> is the position in the storage volume at which to start reading
the data. The value must be 0 or larger. I<--length> is an upper bound of
the amount of data to be downloaded. A negative value is interpreted as
an unsigned long long value to essentially include everything from the
offset to the end of the volume.
=item B<vol-wipe> [I<--pool> I<pool-or-uuid>] [I<--algorithm> I<algorithm>]
I<vol-name-or-key-or-path>
Wipe a volume, ensure data previously on the volume is not accessible to
future reads. I<--pool> I<pool-or-uuid> is the name or UUID of the storage
pool the volume is in.
I<vol-name-or-key-or-path> is the name or key or path of the volume to wipe.
It is possible to choose different wiping algorithms instead of re-writing
volume with zeroes. This can be done via I<--algorithm> switch.
B<Supported algorithms>
zero - 1-pass all zeroes
nnsa - 4-pass NNSA Policy Letter NAP-14.1-C (XVI-8) for
sanitizing removable and non-removable hard disks:
random x2, 0x00, verify.
dod - 4-pass DoD 5220.22-M section 8-306 procedure for
sanitizing removable and non-removable rigid
disks: random, 0x00, 0xff, verify.
bsi - 9-pass method recommended by the German Center of
Security in Information Technologies
(http://www.bsi.bund.de): 0xff, 0xfe, 0xfd, 0xfb,
0xf7, 0xef, 0xdf, 0xbf, 0x7f.
gutmann - The canonical 35-pass sequence described in
Gutmann's paper.
schneier - 7-pass method described by Bruce Schneier in
"Applied Cryptography" (1996): 0x00, 0xff,
random x5.
pfitzner7 - Roy Pfitzner's 7-random-pass method: random x7.
pfitzner33 - Roy Pfitzner's 33-random-pass method: random x33.
random - 1-pass pattern: random.
B<Note>: The availability of algorithms may be limited by the version
of the C<scrub> binary installed on the host.
=item B<vol-dumpxml> [I<--pool> I<pool-or-uuid>] I<vol-name-or-key-or-path>
Output the volume information as an XML dump to stdout.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in. I<vol-name-or-key-or-path> is the name or key or path of the volume
to output the XML of.
=item B<vol-info> [I<--pool> I<pool-or-uuid>] I<vol-name-or-key-or-path>
Returns basic information about the given storage volume.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in. I<vol-name-or-key-or-path> is the name or key or path of the volume
to return information for.
=item B<vol-list> [I<--pool> I<pool-or-uuid>] [I<--details>]
Return the list of volumes in the given storage pool.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool.
The I<--details> option instructs virsh to additionally display volume
type and capacity related information where available.
=item B<vol-pool> [I<--uuid>] I<vol-key-or-path>
Return the pool name or UUID for a given volume. By default, the pool name is
returned. If the I<--uuid> option is given, the pool UUID is returned instead.
I<vol-key-or-path> is the key or path of the volume to return the pool
information for.
=item B<vol-path> [I<--pool> I<pool-or-uuid>] I<vol-name-or-key>
Return the path for a given volume.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in.
I<vol-name-or-key> is the name or key of the volume to return the path for.
=item B<vol-name> I<vol-key-or-path>
Return the name for a given volume.
I<vol-key-or-path> is the key or path of the volume to return the name for.
=item B<vol-key> [I<--pool> I<pool-or-uuid>] I<vol-name-or-path>
Return the volume key for a given volume.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in. I<vol-name-or-path> is the name or path of the volume to return the
volume key for.
=item B<vol-resize> [I<--pool> I<pool-or-uuid>] I<vol-name-or-path>
I<pool-or-uuid> I<capacity> [I<--allocate>] [I<--delta>] [I<--shrink>]
Resize the capacity of the given volume, in bytes.
I<--pool> I<pool-or-uuid> is the name or UUID of the storage pool the volume
is in. I<vol-name-or-key-or-path> is the name or key or path of the volume
to resize. The new capacity might be sparse unless I<--allocate> is
specified. Normally, I<capacity> is the new size, but if I<--delta>
is present, then it is added to the existing size. Attempts to shrink
the volume will fail unless I<--shrink> is present; I<capacity> cannot
be negative unless I<--shrink> is provided, but a negative sign is not
necessary. I<capacity> is a scaled integer (see B<NOTES> above), which
defaults to bytes if there is no suffix. This command is only safe
for storage volumes not in use by an active guest; see also
B<blockresize> for live resizing.
=back
=head1 SECRET COMMANDS
The following commands manipulate "secrets" (e.g. passwords, passphrases and
encryption keys). Libvirt can store secrets independently from their use, and
other objects (e.g. volumes or domains) can refer to the secrets for encryption
or possibly other uses. Secrets are identified using a UUID. See
L<http://libvirt.org/formatsecret.html> for documentation of the XML format
used to represent properties of secrets.
=over 4
=item B<secret-define> I<file>
Create a secret with the properties specified in I<file>, with no associated
secret value. If I<file> does not specify a UUID, choose one automatically.
If I<file> specifies a UUID of an existing secret, replace its properties by
properties defined in I<file>, without affecting the secret value.
=item B<secret-dumpxml> I<secret>
Output properties of I<secret> (specified by its UUID) as an XML dump to stdout.
=item B<secret-set-value> I<secret> I<base64>
Set the value associated with I<secret> (specified by its UUID) to the value
Base64-encoded value I<base64>.
=item B<secret-get-value> I<secret>
Output the value associated with I<secret> (specified by its UUID) to stdout,
encoded using Base64.
=item B<secret-undefine> I<secret>
Delete a I<secret> (specified by its UUID), including the associated value, if
any.
=item B<secret-list> [I<--ephemeral>] [I<--no-ephemeral>]
[I<--private>] [I<--no-private>]
Returns the list of secrets. You may also want to filter the returned secrets
by I<--ephemeral> to list the ephemeral ones, I<--no-ephemeral> to list the
non-ephemeral ones, I<--private> to list the private ones, and
I<--no-private> to list the non-private ones.
=back
=head1 SNAPSHOT COMMANDS
The following commands manipulate domain snapshots. Snapshots take the
disk, memory, and device state of a domain at a point-of-time, and save it
for future use. They have many uses, from saving a "clean" copy of an OS
image to saving a domain's state before a potentially destructive operation.
Snapshots are identified with a unique name. See
L<http://libvirt.org/formatsnapshot.html> for documentation of the XML format
used to represent properties of snapshots.
=over 4
=item B<snapshot-create> I<domain> [I<xmlfile>] {[I<--redefine> [I<--current>]]
| [I<--no-metadata>] [I<--halt>] [I<--disk-only>] [I<--reuse-external>]
[I<--quiesce>] [I<--atomic>] [I<--live>]}
Create a snapshot for domain I<domain> with the properties specified in
I<xmlfile>. Normally, the only properties settable for a domain snapshot
are the <name> and <description> elements, as well as <disks> if
I<--disk-only> is given; the rest of the fields are
ignored, and automatically filled in by libvirt. If I<xmlfile> is
completely omitted, then libvirt will choose a value for all fields.
The new snapshot will become current, as listed by B<snapshot-current>.
If I<--halt> is specified, the domain will be left in an inactive state
after the snapshot is created.
If I<--disk-only> is specified, the snapshot will only include disk
state rather than the usual system checkpoint with vm state. Disk
snapshots are faster than full system checkpoints, but reverting to a
disk snapshot may require fsck or journal replays, since it is like
the disk state at the point when the power cord is abruptly pulled;
and mixing I<--halt> and I<--disk-only> loses any data that was not
flushed to disk at the time.
If I<--redefine> is specified, then all XML elements produced by
B<snapshot-dumpxml> are valid; this can be used to migrate snapshot
hierarchy from one machine to another, to recreate hierarchy for the
case of a transient domain that goes away and is later recreated with
the same name and UUID, or to make slight alterations in the snapshot
metadata (such as host-specific aspects of the domain XML embedded in
the snapshot). When this flag is supplied, the I<xmlfile> argument
is mandatory, and the domain's current snapshot will not be altered
unless the I<--current> flag is also given.
If I<--no-metadata> is specified, then the snapshot data is created,
but any metadata is immediately discarded (that is, libvirt does not
treat the snapshot as current, and cannot revert to the snapshot
unless I<--redefine> is later used to teach libvirt about the
metadata again).
If I<--reuse-external> is specified, and the snapshot XML requests an
external snapshot with a destination of an existing file, then the
destination must exist and be pre-created with correct format and
metadata. The file is then reused; otherwise, a snapshot is refused
to avoid losing contents of the existing files.
If I<--quiesce> is specified, libvirt will try to use guest agent
to freeze and unfreeze domain's mounted file systems. However,
if domain has no guest agent, snapshot creation will fail.
Currently, this requires I<--disk-only> to be passed as well.
If I<--atomic> is specified, libvirt will guarantee that the snapshot
either succeeds, or fails with no changes; not all hypervisors support
this. If this flag is not specified, then some hypervisors may fail
after partially performing the action, and B<dumpxml> must be used to
see whether any partial changes occurred.
If I<--live> is specified, libvirt takes the snapshot while the guest is
running. This increases the size of the memory image of the external
checkpoint. This is currently supported only for external checkpoints.
Existence of snapshot metadata will prevent attempts to B<undefine>
a persistent domain. However, for transient domains, snapshot
metadata is silently lost when the domain quits running (whether
by command such as B<destroy> or by internal guest action).
=item B<snapshot-create-as> I<domain> {[I<--print-xml>]
| [I<--no-metadata>] [I<--halt>] [I<--reuse-external>]} [I<name>]
[I<description>] [I<--disk-only> [I<--quiesce>]] [I<--atomic>]
[[I<--live>] [I<--memspec> B<memspec>]] [I<--diskspec>] B<diskspec>]...
Create a snapshot for domain I<domain> with the given <name> and
<description>; if either value is omitted, libvirt will choose a
value. If I<--print-xml> is specified, then XML appropriate for
I<snapshot-create> is output, rather than actually creating a snapshot.
Otherwise, if I<--halt> is specified, the domain will be left in an
inactive state after the snapshot is created, and if I<--disk-only>
is specified, the snapshot will not include vm state.
The I<--memspec> option can be used to control whether a checkpoint
is internal or external. The I<--memspec> flag is mandatory, followed
by a B<memspec> of the form B<[file=]name[,snapshot=type]>, where
type can be B<no>, B<internal>, or B<external>. To include a literal
comma in B<file=name>, escape it with a second comma. I<--memspec> cannot
be used together with I<--disk-only>.
The I<--diskspec> option can be used to control how I<--disk-only> and
external checkpoints create external files. This option can occur
multiple times, according to the number of <disk> elements in the domain
xml. Each <diskspec> is in the
form B<disk[,snapshot=type][,driver=type][,file=name]>. A I<diskspec>
must be provided for disks backed by block devices as libvirt doesn't
auto-generate file names for those. To include a
literal comma in B<disk> or in B<file=name>, escape it with a second
comma. A literal I<--diskspec> must precede each B<diskspec> unless
all three of I<domain>, I<name>, and I<description> are also present.
For example, a diskspec of "vda,snapshot=external,file=/path/to,,new"
results in the following XML:
<disk name='vda' snapshot='external'>
<source file='/path/to,new'/>
</disk>
If I<--reuse-external> is specified, and the domain XML or I<diskspec>
option requests an external snapshot with a destination of an existing
file, then the destination must exist and be pre-created with correct
format and metadata. The file is then reused; otherwise, a snapshot
is refused to avoid losing contents of the existing files.
If I<--quiesce> is specified, libvirt will try to use guest agent
to freeze and unfreeze domain's mounted file systems. However,
if domain has no guest agent, snapshot creation will fail.
Currently, this requires I<--disk-only> to be passed as well.
If I<--no-metadata> is specified, then the snapshot data is created,
but any metadata is immediately discarded (that is, libvirt does not
treat the snapshot as current, and cannot revert to the snapshot
unless B<snapshot-create> is later used to teach libvirt about the
metadata again). This flag is incompatible with I<--print-xml>.
If I<--atomic> is specified, libvirt will guarantee that the snapshot
either succeeds, or fails with no changes; not all hypervisors support
this. If this flag is not specified, then some hypervisors may fail
after partially performing the action, and B<dumpxml> must be used to
see whether any partial changes occurred.
If I<--live> is specified, libvirt takes the snapshot while the guest is
running. This increases the size of the memory image of the external
checkpoint. This is currently supported only for external checkpoints.
=item B<snapshot-current> I<domain> {[I<--name>] | [I<--security-info>]
| [I<snapshotname>]}
Without I<snapshotname>, this will output the snapshot XML for the domain's
current snapshot (if any). If I<--name> is specified, just the
current snapshot name instead of the full xml. Otherwise, using
I<--security-info> will also include security sensitive information in
the XML.
With I<snapshotname>, this is a request to make the existing named
snapshot become the current snapshot, without reverting the domain.
=item B<snapshot-edit> I<domain> [I<snapshotname>] [I<--current>]
{[I<--rename>] | [I<--clone>]}
Edit the XML configuration file for I<snapshotname> of a domain. If
both I<snapshotname> and I<--current> are specified, also force the
edited snapshot to become the current snapshot. If I<snapshotname>
is omitted, then I<--current> must be supplied, to edit the current
snapshot.
This is equivalent to:
virsh snapshot-dumpxml dom name > snapshot.xml
vi snapshot.xml (or make changes with your other text editor)
virsh snapshot-create dom snapshot.xml --redefine [--current]
except that it does some error checking.
The editor used can be supplied by the C<$VISUAL> or C<$EDITOR> environment
variables, and defaults to C<vi>.
If I<--rename> is specified, then the edits can change the snapshot
name. If I<--clone> is specified, then changing the snapshot name
will create a clone of the snapshot metadata. If neither is specified,
then the edits must not change the snapshot name. Note that changing
a snapshot name must be done with care, since the contents of some
snapshots, such as internal snapshots within a single qcow2 file, are
accessible only from the original name.
=item B<snapshot-info> I<domain> {I<snapshot> | I<--current>}
Output basic information about a named <snapshot>, or the current snapshot
with I<--current>.
=item B<snapshot-list> I<domain> [I<--metadata>] [I<--no-metadata>]
[{I<--parent> | I<--roots> | [{I<--tree> | I<--name>}]}]
[{[I<--from>] B<snapshot> | I<--current>} [I<--descendants>]]
[I<--leaves>] [I<--no-leaves>] [I<--inactive>] [I<--active>]
[I<--disk-only>] [I<--internal>] [I<--external>]
List all of the available snapshots for the given domain, defaulting
to show columns for the snapshot name, creation time, and domain state.
If I<--parent> is specified, add a column to the output table giving
the name of the parent of each snapshot. If I<--roots> is specified,
the list will be filtered to just snapshots that have no parents.
If I<--tree> is specified, the output will be in a tree format, listing
just snapshot names. These three options are mutually exclusive. If
I<--name> is specified only the snapshot name is printed. This option is
mutually exclusive with I<--tree>.
If I<--from> is provided, filter the list to snapshots which are
children of the given B<snapshot>; or if I<--current> is provided,
start at the current snapshot. When used in isolation or with
I<--parent>, the list is limited to direct children unless
I<--descendants> is also present. When used with I<--tree>, the
use of I<--descendants> is implied. This option is not compatible
with I<--roots>. Note that the starting point of I<--from> or
I<--current> is not included in the list unless the I<--tree>
option is also present.
If I<--leaves> is specified, the list will be filtered to just
snapshots that have no children. Likewise, if I<--no-leaves> is
specified, the list will be filtered to just snapshots with
children. (Note that omitting both options does no filtering,
while providing both options will either produce the same list
or error out depending on whether the server recognizes the flags).
Filtering options are not compatible with I<--tree>.
If I<--metadata> is specified, the list will be filtered to just
snapshots that involve libvirt metadata, and thus would prevent
B<undefine> of a persistent domain, or be lost on B<destroy> of
a transient domain. Likewise, if I<--no-metadata> is specified,
the list will be filtered to just snapshots that exist without
the need for libvirt metadata.
If I<--inactive> is specified, the list will be filtered to snapshots
that were taken when the domain was shut off. If I<--active> is
specified, the list will be filtered to snapshots that were taken
when the domain was running, and where the snapshot includes the
memory state to revert to that running state. If I<--disk-only> is
specified, the list will be filtered to snapshots that were taken
when the domain was running, but where the snapshot includes only
disk state.
If I<--internal> is specified, the list will be filtered to snapshots
that use internal storage of existing disk images. If I<--external>
is specified, the list will be filtered to snapshots that use external
files for disk images or memory state.
=item B<snapshot-dumpxml> I<domain> I<snapshot> [I<--security-info>]
Output the snapshot XML for the domain's snapshot named I<snapshot>.
Using I<--security-info> will also include security sensitive information.
Use B<snapshot-current> to easily access the XML of the current snapshot.
=item B<snapshot-parent> I<domain> {I<snapshot> | I<--current>}
Output the name of the parent snapshot, if any, for the given
I<snapshot>, or for the current snapshot with I<--current>.
=item B<snapshot-revert> I<domain> {I<snapshot> | I<--current>}
[{I<--running> | I<--paused>}] [I<--force>]
Revert the given domain to the snapshot specified by I<snapshot>, or to
the current snapshot with I<--current>. Be aware
that this is a destructive action; any changes in the domain since the last
snapshot was taken will be lost. Also note that the state of the domain after
snapshot-revert is complete will be the state of the domain at the time
the original snapshot was taken.
Normally, reverting to a snapshot leaves the domain in the state it was
at the time the snapshot was created, except that a disk snapshot with
no vm state leaves the domain in an inactive state. Passing either the
I<--running> or I<--paused> flag will perform additional state changes
(such as booting an inactive domain, or pausing a running domain). Since
transient domains cannot be inactive, it is required to use one of these
flags when reverting to a disk snapshot of a transient domain.
There are two cases where a snapshot revert involves extra risk, which
requires the use of I<--force> to proceed. One is the case of a
snapshot that lacks full domain information for reverting
configuration (such as snapshots created prior to libvirt 0.9.5);
since libvirt cannot prove that the current configuration matches what
was in use at the time of the snapshot, supplying I<--force> assures
libvirt that the snapshot is compatible with the current configuration
(and if it is not, the domain will likely fail to run). The other is
the case of reverting from a running domain to an active state where a
new hypervisor has to be created rather than reusing the existing
hypervisor, because it implies drawbacks such as breaking any existing
VNC or Spice connections; this condition happens with an active
snapshot that uses a provably incompatible configuration, as well as
with an inactive snapshot that is combined with the I<--start> or
I<--pause> flag.
=item B<snapshot-delete> I<domain> {I<snapshot> | I<--current>} [I<--metadata>]
[{I<--children> | I<--children-only>}]
Delete the snapshot for the domain named I<snapshot>, or the current
snapshot with I<--current>. If this snapshot
has child snapshots, changes from this snapshot will be merged into the
children. If I<--children> is passed, then delete this snapshot and any
children of this snapshot. If I<--children-only> is passed, then delete
any children of this snapshot, but leave this snapshot intact. These
two flags are mutually exclusive.
If I<--metadata> is specified, then only delete the snapshot metadata
maintained by libvirt, while leaving the snapshot contents intact for
access by external tools; otherwise deleting a snapshot also removes
the data contents from that point in time.
=back
=head1 NWFILTER COMMANDS
The following commands manipulate network filters. Network filters allow
filtering of the network traffic coming from and going to virtual machines.
Individual network traffic filters are written in XML and may contain
references to other network filters, describe traffic filtering rules,
or contain both. Network filters are referenced by virtual machines
from within their interface description. A network filter may be referenced
by multiple virtual machines' interfaces.
=over 4
=item B<nwfilter-define> I<xmlfile>
Make a new network filter known to libvirt. If a network filter with
the same name already exists, it will be replaced with the new XML.
Any running virtual machine referencing this network filter will have
its network traffic rules adapted. If for any reason the network traffic
filtering rules cannot be instantiated by any of the running virtual
machines, then the new XML will be rejected.
=item B<nwfilter-undefine> I<nwfilter-name>
Delete a network filter. The deletion will fail if any running virtual
machine is currently using this network filter.
=item B<nwfilter-list>
List all of the available network filters.
=item B<nwfilter-dumpxml> I<nwfilter-name>
Output the network filter XML.
=item B<nwfilter-edit> I<nwfilter-name>
Edit the XML of a network filter.
This is equivalent to:
virsh nwfilter-dumpxml myfilter > myfilter.xml
vi myfilter.xml (or make changes with your other text editor)
virsh nwfilter-define myfilter.xml
except that it does some error checking.
The new network filter may be rejected due to the same reason as
mentioned in I<nwfilter-define>.
The editor used can be supplied by the C<$VISUAL> or C<$EDITOR> environment
variables, and defaults to C<vi>.
=back
=head1 HYPERVISOR-SPECIFIC COMMANDS
NOTE: Use of the following commands is B<strongly> discouraged. They
can cause libvirt to become confused and do the wrong thing on subsequent
operations. Once you have used these commands, please do not report
problems to the libvirt developers; the reports will be ignored. If
you find that these commands are the only way to accomplish something,
then it is better to request that the feature be added as a first-class
citizen in the regular libvirt library.
=over 4
=item B<qemu-attach> I<pid>
Attach an externally launched QEMU process to the libvirt QEMU driver.
The QEMU process must have been created with a monitor connection
using the UNIX driver. Ideally the process will also have had the
'-name' argument specified.
=over 4
$ qemu-kvm -cdrom ~/demo.iso \
-monitor unix:/tmp/demo,server,nowait \
-name foo \
-uuid cece4f9f-dff0-575d-0e8e-01fe380f12ea &
$ QEMUPID=$!
$ virsh qemu-attach $QEMUPID
=back
Not all functions of libvirt are expected to work reliably after
attaching to an externally launched QEMU process. There may be
issues with the guest ABI changing upon migration, and hotunplug
may not work.
=item B<qemu-monitor-command> I<domain> { [I<--hmp>] | [I<--pretty>] }
I<command>...
Send an arbitrary monitor command I<command> to domain I<domain> through the
qemu monitor. The results of the command will be printed on stdout. If
I<--hmp> is passed, the command is considered to be a human monitor command
and libvirt will automatically convert it into QMP if needed. In that case
the result will also be converted back from QMP. If I<--pretty> is given,
and the monitor uses QMP, then the output will be pretty-printed. If more
than one argument is provided for I<command>, they are concatenated with a
space in between before passing the single command to the monitor.
=item B<qemu-agent-command> I<domain> [I<--timeout> I<seconds> | I<--async> |
I<--block>] I<command>...
Send an arbitrary guest agent command I<command> to domain I<domain> through
qemu agent.
I<--timeout>, I<--async> and I<--block> options are exclusive.
I<--timeout> requires timeout seconds I<seconds> and it must be positive.
When I<--aysnc> is given, the command waits for timeout whether success or
failed. And when I<--block> is given, the command waits forever with blocking
timeout.
=item B<qemu-monitor-event> [I<domain>] [I<--event> I<event-name>] [I<--loop>]
[I<--timeout> I<seconds>] [I<--pretty>] [I<--regex>] [I<--no-case>]
Wait for arbitrary QEMU monitor events to occur, and print out the
details of events as they happen. The events can optionally be filtered
by I<domain> or I<event-name>. The 'query-events' QMP command can be
used via I<qemu-monitor-command> to learn what events are supported.
If I<--regex> is used, I<event-name> is a basic regular expression
instead of a literal string. If I<--no-case> is used, I<event-name>
will match case-insensitively.
By default, this command is one-shot, and returns success once an event
occurs; you can send SIGINT (usually via C<Ctrl-C>) to quit immediately.
If I<--timeout> is specified, the command gives up waiting for events
after I<seconds> have elapsed. With I<--loop>, the command prints all
events until a timeout or interrupt key. If I<--pretty> is specified,
any JSON event details are pretty-printed for better legibility.
=item B<lxc-enter-namespace> I<domain> -- /path/to/binary [arg1, [arg2, ...]]
Enter the namespace of I<domain> and execute the command C</path/to/binary>
passing the requested args. The binary path is relative to the container
root filesystem, not the host root filesystem. The binary will inherit the
environment variables / console visible to virsh. This command only works
when connected to the LXC hypervisor driver. This command succeeds only
if C</path/to/binary> has 0 exit status.
=back
=head1 ENVIRONMENT
The following environment variables can be set to alter the behaviour
of C<virsh>
=over 4
=item VIRSH_DEBUG=<0 to 4>
Turn on verbose debugging of virsh commands. Valid levels are
=over 4
=item * VIRSH_DEBUG=0
DEBUG - Messages at ALL levels get logged
=item * VIRSH_DEBUG=1
INFO - Logs messages at levels INFO, NOTICE, WARNING and ERROR
=item * VIRSH_DEBUG=2
NOTICE - Logs messages at levels NOTICE, WARNING and ERROR
=item * VIRSH_DEBUG=3
WARNING - Logs messages at levels WARNING and ERROR
=item * VIRSH_DEBUG=4
ERROR - Messages at only ERROR level gets logged.
=back
=item VIRSH_LOG_FILE=C<LOGFILE>
The file to log virsh debug messages.
=item VIRSH_DEFAULT_CONNECT_URI
The hypervisor to connect to by default. Set this to a URI, in the same
format as accepted by the B<connect> option. This environment variable
is deprecated in favour of the global B<LIBVIRT_DEFAULT_URI> variable
which serves the same purpose.
=item LIBVIRT_DEFAULT_URI
The hypervisor to connect to by default. Set this to a URI, in the
same format as accepted by the B<connect> option. This overrides
the default URI set in any client config file and prevents libvirt
from probing for drivers.
=item VISUAL
The editor to use by the B<edit> and related options.
=item EDITOR
The editor to use by the B<edit> and related options, if C<VISUAL>
is not set.
=item VIRSH_HISTSIZE
The number of commands to remember in the command history. The
default value is 500.
=item LIBVIRT_DEBUG=LEVEL
Turn on verbose debugging of all libvirt API calls. Valid levels are
=over 4
=item * LIBVIRT_DEBUG=1
Messages at level DEBUG or above
=item * LIBVIRT_DEBUG=2
Messages at level INFO or above
=item * LIBVIRT_DEBUG=3
Messages at level WARNING or above
=item * LIBVIRT_DEBUG=4
Messages at level ERROR or above
=back
For further information about debugging options consult C<http://libvirt.org/logging.html>
=back
=head1 BUGS
Report any bugs discovered to the libvirt community via the mailing
list C<http://libvirt.org/contact.html> or bug tracker C<http://libvirt.org/bugs.html>.
Alternatively report bugs to your software distributor / vendor.
=head1 AUTHORS
Please refer to the AUTHORS file distributed with libvirt.
Based on the xm man page by:
Sean Dague <sean at dague dot net>
Daniel Stekloff <dsteklof at us dot ibm dot com>
=head1 COPYRIGHT
Copyright (C) 2005, 2007-2014 Red Hat, Inc., and the authors listed in the
libvirt AUTHORS file.
=head1 LICENSE
virsh is distributed under the terms of the GNU LGPL v2+.
This is free software; see the source for copying conditions. There
is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR
PURPOSE
=head1 SEE ALSO
L<virt-install(1)>, L<virt-xml-validate(1)>, L<virt-top(1)>, L<virt-df(1)>,
L<http://www.libvirt.org/>
=cut
|