From 236c7e158d6d3482afa29505d7da718a5598c939 Mon Sep 17 00:00:00 2001 From: Wai-Hong Tam Date: Mon, 3 Aug 2020 15:59:33 -0700 Subject: battery: Update the default powerd's full factor value Use the same default value as powerd, i.e. 97% instead of 94%. The value comes from: src/platform2/power_manager/default_prefs/power_supply_full_factor BRANCH=None BUG=b:162604872 TEST=Checked EC showing the same Display percentage as the UI. Change-Id: Ia8547915251ea80bc663b5f15435060acacf9021 Signed-off-by: Wai-Hong Tam Reviewed-on: https://chromium-review.googlesource.com/c/chromiumos/platform/ec/+/2335887 Reviewed-by: Jett Rink Reviewed-on: https://chromium-review.googlesource.com/c/chromiumos/platform/ec/+/3872708 Auto-Submit: Daisuke Nojiri Commit-Queue: Daisuke Nojiri Tested-by: Daisuke Nojiri --- include/config.h | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-) diff --git a/include/config.h b/include/config.h index 982ce4fbc4..91d4b5ba89 100644 --- a/include/config.h +++ b/include/config.h @@ -503,9 +503,10 @@ #define CONFIG_BATT_HOST_SHUTDOWN_PERCENTAGE 4 /* - * Powerd's full_factor. + * Powerd's full_factor. The value comes from: + * src/platform2/power_manager/default_prefs/power_supply_full_factor */ -#define CONFIG_BATT_HOST_FULL_FACTOR 94 +#define CONFIG_BATT_HOST_FULL_FACTOR 97 /* * Expose some data when it is needed. -- cgit v1.2.1