.TH dlt.conf 5 "September 19, 2012" "version 2.7.1 Stable" "USER COMMANDS" .SH NAME dlt.conf \- DLT daemon configuration file .SH DESCRIPTION The DLT daemon is the central place where logs and traces are gathered from different applications, stored temporarily or permanently and transferred to a DLT client application, which can run directly on the GENIVI system or more likely on a external tester device. .PP The configuration file dlt.conf allows to configure the different runtime behaviour of the dlt-daemon. The configuration file is loaded during startup of dlt-daemon. .PP dlt-daemon loads by default the configuration file /etc/dlt.conf. An alternative configuration file can be loaded with the option \-c. .SH GENERAL OPTIONS .TP .B Verbose If set to 1 DLT daemon is started in dubug mode, so that all internal debug information is printed out on the console. .IP Default: 0 .TP .B Daemonize If set to 1 DLT daemon is started in background as daemon. This option is only needed in System V init systems. In systemd based startup systems the daemon is started by spawning own process. .IP Default: 0 .TP .B SendSerialHeader If set to 1 DLT daemon sends each DLT message to the client with prepanding the serial header "DLS0x01". .IP Default: 0 .TP .B SendContextRegistration If set to 1 each context which is registered from an application in the DLT daemon generates a message to inform the DLT client about the new context. .IP Default: 0 .TP .B SendMessageTime If set to 1 DLt daemon sends each second a DLT control message to the client with the current timestamp from the system. .IP Default: 0 .TP .B ECUId This value sets the ECU Id, which is sent with each DLT message. .IP Default: ECU1 .TP .B SharedMemorySize This value sets the size of the shared memory, which is used to exchange DLT messages between applications and daemon. This value is defined in bytes. If this value is changed the system must be rebooted to take effect. .IP Default: 100000 .TP .B PersistanceStoragePath This is the directory path, where the DLT daemon stores its runtime configuration. Runtime configuration includes stored log levels, trace status and changed logging mode. .IP Default: /tmp .SH OFFLINE TRACE OPTIONS .TP .B OfflineTraceDirectory If this option is set, offline trace is enabled. This value sets the directory path to the offline trace memory. The directory must already exist. .IP Default: Offline tracing is disabled. .TP .B OfflineTraceFileSize This value defines the max size of a offline trace file, if offline trace is enabled. This value is defined in bytes. If the files size of the current used log file is exceeded, a new log file is created. .IP Default: 1000000 .TP .B OfflineTraceMaxSize This value defines the max offline Trace memory size, if offline trace is enabled. This value is defined in bytes. If the overall offline trace size is excedded, the oldest log files are deleted, until a new trace file fits the overall offline trace max size. .IP Default: 4000000 .SH LOCAL CONSOLE OUTPUT OPTIONS .TP .B PrintASCII Prints each received DLT message from the application in ASCII to the local console. This option should only be anabled for debugging purpose. .IP Default: Function is disabled .TP .B PrintHex Prints each received DLT message from the application in ASCII to the local console. The payload is printed in Hex. This option should only be anabled for debugging purpose. .IP Default: Function is disabled .TP .B PrintHeadersOnly Prints each received DLT message from the application in ASCII to the local console. Only the header is printed. This option should only be anabled for debugging purpose. .IP Default: Function is disabled .SH SERIAL CLIENT OPTIONS .TP .B RS232DeviceName If this value is set to a serial device name, e.g. /dev/ttyS0, a serial port is used for logging to a client. .IP Default: Serial port for logging is disabled .TP .B RS232Baudrate The used serial baud rate, if serial loggin is enabled. The RS232DeviceName must be set to enable serial logging. .IP Default: 115200 .TP .B RS232SyncSerialHeader If serial logging is enabled, each received DLT message is checked to contain a serial header. If the DLT message contains no serial header, the message is ignored. .IP Default: Function is disabled .SH TCP CLIENT OPTIONS .TP .B TCPSyncSerialHeader Each received DLT message on a TCP connection is checked to contain a serial header. If the DLT message contains no serial header, the message is ignored. .SH ECU Software version info .TP .B SendECUSoftwareVersion Send periodic ECU version info. 0=disabled, 1=enabled. .IP Default: 0 .TP .B PathToECUSoftwareVersion Absolute path to file storing version information - if disabled the DLT version will be send. .SH AUTHOR Alexander Wenzel (alexander.aw.wenzel (at) bmw.de) .SH SEE ALSO dlt(1)